Skip to menu Skip to content Skip to footer

2009

Journal Article

Minimally Invasive Ultrasound Method for Intra-Articular Diagnostics of Cartilage Degeneration

Virén, T., Saarakkala, S., Kaleva, E., Nieminen, H. J., Jurvelin, J. S. and Töyräs, J. (2009). Minimally Invasive Ultrasound Method for Intra-Articular Diagnostics of Cartilage Degeneration. Ultrasound in Medicine and Biology, 35 (9), 1546-1554. doi: 10.1016/j.ultrasmedbio.2009.04.004

Minimally Invasive Ultrasound Method for Intra-Articular Diagnostics of Cartilage Degeneration

2009

Journal Article

Effects of Ultrasound Beam Angle and Surface Roughness on the Quantitative Ultrasound Parameters of Articular Cartilage

Kaleva, E., Saarakkala, S., Jurvelin, J. S., Virén, T. and Töyräs, J. (2009). Effects of Ultrasound Beam Angle and Surface Roughness on the Quantitative Ultrasound Parameters of Articular Cartilage. Ultrasound in Medicine and Biology, 35 (8), 1344-1351. doi: 10.1016/j.ultrasmedbio.2009.03.009

Effects of Ultrasound Beam Angle and Surface Roughness on the Quantitative Ultrasound Parameters of Articular Cartilage

2009

Journal Article

Ultrasound Backscatter Imaging Provides Frequency-Dependent Information on Structure, Composition and Mechanical Properties of Human Trabecular Bone

Karjalainen, Janne P., Töyräs, Juha, Riekkinen, Ossi, Hakulinen, Mikko and Jurvelin, Jukka S. (2009). Ultrasound Backscatter Imaging Provides Frequency-Dependent Information on Structure, Composition and Mechanical Properties of Human Trabecular Bone. Ultrasound in Medicine and Biology, 35 (8), 1376-1384. doi: 10.1016/j.ultrasmedbio.2009.03.011

Ultrasound Backscatter Imaging Provides Frequency-Dependent Information on Structure, Composition and Mechanical Properties of Human Trabecular Bone

2009

Journal Article

Differences in Acoustic Properties of Intact and Degenerated Human Patellar Cartilage During Compression

Kiviranta, Panu, Lammentausta, Eveliina, Töyräs, Juha, Nieminen, Heikki J., Julkunen, Petro, Kiviranta, Ilkka and Jurvelin, Jukka S. (2009). Differences in Acoustic Properties of Intact and Degenerated Human Patellar Cartilage During Compression. Ultrasound in Medicine and Biology, 35 (8), 1367-1375. doi: 10.1016/j.ultrasmedbio.2009.03.003

Differences in Acoustic Properties of Intact and Degenerated Human Patellar Cartilage During Compression

2009

Journal Article

Accuracy of automatic analysis of ambulatory recordings of nocturnal breathing disorders is significantly instrumentation dependent

Tiihonen, P., Hukkanen, T., Tuomilehto, H., Mervaala, E., Paakkonen, A. and Toyras, J. (2009). Accuracy of automatic analysis of ambulatory recordings of nocturnal breathing disorders is significantly instrumentation dependent. Journal of Medical Engineering and Technology, 33 (5), 386-393. doi: 10.1080/03091900902739999

Accuracy of automatic analysis of ambulatory recordings of nocturnal breathing disorders is significantly instrumentation dependent

2009

Journal Article

Strain-Dependent Modulation of Ultrasound Speed in Articular Cartilage Under Dynamic Compression

Lötjönen, Pauno, Julkunen, Petro, Töyräs, Juha, Lammi, Mikko J., Jurvelin, Jukka S. and Nieminen, Heikki J. (2009). Strain-Dependent Modulation of Ultrasound Speed in Articular Cartilage Under Dynamic Compression. Ultrasound in Medicine and Biology, 35 (7), 1177-1184. doi: 10.1016/j.ultrasmedbio.2009.03.002

Strain-Dependent Modulation of Ultrasound Speed in Articular Cartilage Under Dynamic Compression

2009

Journal Article

Effects of ultrasound frequency, temporal sampling frequency, and spatial sampling step on the quantitative ultrasound parameters of articular cartilage

Kaleva, Erna, Töyräs, Juha, Jurvelin, Jukka S., Virén, Tuomas and Saarakkala, Simo (2009). Effects of ultrasound frequency, temporal sampling frequency, and spatial sampling step on the quantitative ultrasound parameters of articular cartilage. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 56 (7) 5116864, 1383-1393. doi: 10.1109/TUFFC.2009.1194

Effects of ultrasound frequency, temporal sampling frequency, and spatial sampling step on the quantitative ultrasound parameters of articular cartilage

2009

Journal Article

Fabrication and testing of polyimide-based microelectrode arrays for cortical mapping of evoked potentials

Myllymaa, Sami, Myllymaa, Katja, Korhonen, Hannu, Töyräs, Juha, Jääskeläinen, Juha E., Djupsund, Kaj, Tanila, Heikki and Lappalainen, Reijo (2009). Fabrication and testing of polyimide-based microelectrode arrays for cortical mapping of evoked potentials. Biosensors and Bioelectronics, 24 (10), 3067-3072. doi: 10.1016/j.bios.2009.03.028

Fabrication and testing of polyimide-based microelectrode arrays for cortical mapping of evoked potentials

2009

Journal Article

Evaluation of a novel ambulatory device for screening of sleep apnea

Tiihonen, Pekka, Hukkanen, Taina, Tuomilehto, Henri, Mervaala, Esa and Töyräs, Juha (2009). Evaluation of a novel ambulatory device for screening of sleep apnea. Telemedicine and e-Health, 15 (3), 283-289. doi: 10.1089/tmj.2008.0118

Evaluation of a novel ambulatory device for screening of sleep apnea

2009

Journal Article

Contrast agent-enhanced computed tomography of articular cartilage: Association with tissue composition and properties

Silvast, T. S., Jurvelin, J. S., Aula, A. S., Lammi, M. J. and Toyras, J. (2009). Contrast agent-enhanced computed tomography of articular cartilage: Association with tissue composition and properties. Acta Radiologica, 50 (1), 78-85. doi: 10.1080/02841850802572526

Contrast agent-enhanced computed tomography of articular cartilage: Association with tissue composition and properties

2009

Journal Article

Effect of Bone Marrow on Acoustic Properties of Trabecular Bone - 3D Finite Difference Modeling Study

Aula, A. S., Töyräs, J., Hakulinen, M. A. and Jurvelin, J. S. (2009). Effect of Bone Marrow on Acoustic Properties of Trabecular Bone - 3D Finite Difference Modeling Study. Ultrasound in Medicine and Biology, 35 (2), 308-318. doi: 10.1016/j.ultrasmedbio.2008.08.002

Effect of Bone Marrow on Acoustic Properties of Trabecular Bone - 3D Finite Difference Modeling Study

2009

Journal Article

Quantitative assessment of articular cartilage using high-frequency ultrasound: Research findings and diagnostic prospects

Nieminen, Heikki J., Zheng, Y. P., Saarakkala, S., Wang, Q., Töyräs, J., Huang, Y. P. and Jurvelin, J. S. (2009). Quantitative assessment of articular cartilage using high-frequency ultrasound: Research findings and diagnostic prospects. Critical Reviews in Biomedical Engineering, 37 (6), 461-494. doi: 10.1615/CritRevBiomedEng.v37.i6.20

Quantitative assessment of articular cartilage using high-frequency ultrasound: Research findings and diagnostic prospects

2009

Journal Article

pQCT study on diffusion and equilibrium distribution of iodinated anionic contrast agent in human articular cartilage - associations to matrix composition and integrity

Silvast, T. S., Jurvelin, J. S., Lammi, M. J. and Töyräs, J. (2009). pQCT study on diffusion and equilibrium distribution of iodinated anionic contrast agent in human articular cartilage - associations to matrix composition and integrity. Osteoarthritis and Cartilage, 17 (1), 26-32. doi: 10.1016/j.joca.2008.05.012

pQCT study on diffusion and equilibrium distribution of iodinated anionic contrast agent in human articular cartilage - associations to matrix composition and integrity

2009

Journal Article

Design, construction and evaluation of an ambulatory device for screening of sleep apnea

Tiihonen, Pekka, Päkkönen, A., Mervaala, E., Hukkanen, T. and Töyräs, J. (2009). Design, construction and evaluation of an ambulatory device for screening of sleep apnea. Medical and Biological Engineering and Computing, 47 (1), 59-66. doi: 10.1007/s11517-008-0418-8

Design, construction and evaluation of an ambulatory device for screening of sleep apnea

2008

Journal Article

Dual-frequency ultrasound technique minimizes errors induced by soft tissue in ultrasound bone densitometry

Karjalainen, J., Töyräs, J., Rikkonen, T., Jurvelin, J. S. and Riekkinen, O. (2008). Dual-frequency ultrasound technique minimizes errors induced by soft tissue in ultrasound bone densitometry. Acta Radiologica, 49 (9), 1038-1041. doi: 10.1080/02841850802325982

Dual-frequency ultrasound technique minimizes errors induced by soft tissue in ultrasound bone densitometry

2008

Journal Article

Dual-Frequency Ultrasound-New Pulse-Echo Technique for Bone Densitometry

Riekkinen, O., Hakulinen, M. A., Töyräs, J. and Jurvelin, J. S. (2008). Dual-Frequency Ultrasound-New Pulse-Echo Technique for Bone Densitometry. Ultrasound in Medicine and Biology, 34 (10), 1703-1708. doi: 10.1016/j.ultrasmedbio.2008.03.018

Dual-Frequency Ultrasound-New Pulse-Echo Technique for Bone Densitometry

2008

Journal Article

Indentation diagnostics of cartilage degeneration

Kiviranta, P., Lammentausta, E., Töyräs, J., Kiviranta, I. and Jurvelin, J. S. (2008). Indentation diagnostics of cartilage degeneration. Osteoarthritis and Cartilage, 16 (7), 796-804. doi: 10.1016/j.joca.2007.10.016

Indentation diagnostics of cartilage degeneration

2008

Journal Article

The zonal architecture of human articular cartilage described by T2 relaxation time in the presence of Gd-DTPA2-

Kurkijärvi, Jatta E., Nissi, Mikko J., Rieppo, Jarno, Töyräs, Juha, Kiviranta, Ilkka, Nieminen, Miika T. and Jurvelin, Jukka S. (2008). The zonal architecture of human articular cartilage described by T2 relaxation time in the presence of Gd-DTPA2- . Magnetic Resonance Imaging, 26 (5), 602-607. doi: 10.1016/j.mri.2007.10.013

The zonal architecture of human articular cartilage described by T2 relaxation time in the presence of Gd-DTPA2-

2008

Journal Article

A portable device for intensive care brain function monitoring with event-related potentials

Tiihonen, Pekka, Kinnunen, Jukka, Töyräs, Juha, Mervaala, Esa and Pääkkönen, Ari (2008). A portable device for intensive care brain function monitoring with event-related potentials. Computer Methods and Programs in Biomedicine, 89 (1), 83-92. doi: 10.1016/j.cmpb.2007.10.010

A portable device for intensive care brain function monitoring with event-related potentials

2008

Journal Article

In-Vitro Comparison of Time-Domain, Frequency-Domain and Wavelet Ultrasound Parameters in Diagnostics of Cartilage Degeneration

Kaleva, E., Saarakkala, S., Töyräs, J., Nieminen, H. J. and Jurvelin, J. S. (2008). In-Vitro Comparison of Time-Domain, Frequency-Domain and Wavelet Ultrasound Parameters in Diagnostics of Cartilage Degeneration. Ultrasound in Medicine and Biology, 34 (1), 155-159. doi: 10.1016/j.ultrasmedbio.2007.06.028

In-Vitro Comparison of Time-Domain, Frequency-Domain and Wavelet Ultrasound Parameters in Diagnostics of Cartilage Degeneration