2013 Journal Article Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapyCrowe, Scott B., Kairn, Tanya, Middlebrook, Nigel, Hill, Brendan, Christie, David R. H., Knight, Richard T., Kenny, John, Langton, Christian M. and Trapp, Jamie V. (2013). Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity modulated and volumetric modulated arc radiotherapy. Journal of Medical Radiation Sciences, 60 (4), 131-138. doi: 10.1002/jmrs.24 |
2013 Journal Article Correcting radiation survey data to account for increased leakage during intensity modulated radiotherapy treatmentsKairn, T., Crowe, S. B. and Trapp, J. V. (2013). Correcting radiation survey data to account for increased leakage during intensity modulated radiotherapy treatments. Medical Physics, 40 (11) 111708. doi: 10.1118/1.4823776 |
2013 Journal Article Monte Carlo-based diode design for correction-less small field dosimetryCharles, P. H., Crowe, S. B., Kairn, T., Knight, R. T., Hill, B., Kenny, J., Langton, C. M. and Trapp, J. V. (2013). Monte Carlo-based diode design for correction-less small field dosimetry. Physics in Medicine and Biology, 58 (13), 4501-4512. doi: 10.1088/0031-9155/58/13/4501 |
2013 Journal Article The appearance and effects of metallic implants in CT imagesKairn, T., Crowe, S. B., Fogg, P. and Trapp, J. V. (2013). The appearance and effects of metallic implants in CT images. Australasian Physical and Engineering Sciences in Medicine, 36 (2), 209-217. doi: 10.1007/s13246-013-0197-x |
2013 Conference Publication A simple method for EPID-based in vivo dosimetry for radiotherapy treatments of head-and-neck cancersKairn, T., Crowe, S. B. and Trapp, J. V. (2013). A simple method for EPID-based in vivo dosimetry for radiotherapy treatments of head-and-neck cancers. World Congress on Medical Physics and Biomedical Engineering, Beijing, China, 26-31 May 2012. Heidelberg, Germany: Springer. doi: 10.1007/978-3-642-29305-4_454 |
2013 Conference Publication Monte Carlo evaluation of collapsed-cone convolution calculations in head and neck radiotherapy treatment plansCrowe, S. B., Kairn, T., Trapp, J. V. and Fielding, A. L. (2013). Monte Carlo evaluation of collapsed-cone convolution calculations in head and neck radiotherapy treatment plans. World Congress on Medical Physics and Biomedical Engineering, Beijing, China, 26-31 May 2012. Heidelberg, Germany: Springer. doi: 10.1007/978-3-642-29305-4_474 |
2013 Conference Publication Experimental evaluation of MCDTK, the Monte Carlo DICOM tool-kitCrowe, S. B., Kairn, T., Trapp, J. V. and Fielding, A. L. (2013). Experimental evaluation of MCDTK, the Monte Carlo DICOM tool-kit. World Congress on Medical Physics and Biomedical Engineering, Beijing, China, 26-31 May 2012. Heidelberg, Germany: Springer. doi: 10.1007/978-3-642-29305-4_475 |
2013 Conference Publication Dosimetric effects of a high-density spinal implantKairn, T., Crowe, S. B., Kenny, J., Mitchell, J., Burke, M., Schlect, D. and Trapp, J. V. (2013). Dosimetric effects of a high-density spinal implant. 7th International Conference on 3D Radiation Dosimetry (IC3DDose), Sydney, Australia, 4-8 December 2012. Bristol, United Kingdom: Institute of Physics Publishing. doi: 10.1088/1742-6596/444/1/012108 |
2012 Journal Article The effect of very small air gaps on small field dosimetryCharles, P. H., Crowe, S. B., Kairn, T., Kenny, J., Lehmann, J., Lye, J., Dunn, L., Hill, B., Knight, R. T., Langton, C. M. and Trapp, J. V. (2012). The effect of very small air gaps on small field dosimetry. Physics in Medicine and Biology, 57 (21), 6947-6960. doi: 10.1088/0031-9155/57/21/6947 |
2012 Journal Article Monte Carlo verification of gel dosimetry measurements for stereotactic radiotherapyKairn, T., Taylor, M. L., Crowe, S. B., Dunn, L., Franich, R. D., Kenny, J., Knight, R. T. and Trapp, J. V. (2012). Monte Carlo verification of gel dosimetry measurements for stereotactic radiotherapy. Physics in Medicine and Biology, 57 (11), 3359-3369. doi: 10.1088/0031-9155/57/11/3359 |
2011 Conference Publication Investigation of stereotactic radiotherapy dose using dosimetry film and Monte Carlo simulationsKairn, T., Crowe, S., Kenny, J. and Trapp, J. V. (2011). Investigation of stereotactic radiotherapy dose using dosimetry film and Monte Carlo simulations. doi: 10.1016/j.radmeas.2011.06.024 |
2010 Journal Article Technical note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distributionKairn, T., Kenny, J., Crowe, S. B., Fielding, A. L., Franich, R. D., Johnston, P. N., Knight, R. T., Langton, C. M., Schlect, D. and Trapp, J. V. (2010). Technical note: Modeling a complex micro-multileaf collimator using the standard BEAMnrc distribution. Medical Physics, 37 (4), 1761-1767. doi: 10.1118/1.3355873 |
2009 Journal Article Effects of collimator backscatter in an Elekta linac by Monte Carlo simulationKairn, T., Crowe, S. B., Poole, C. M. and Fielding, A. L. (2009). Effects of collimator backscatter in an Elekta linac by Monte Carlo simulation. Australasian Physical and Engineering Sciences in Medicine, 32 (3), 129-135. doi: 10.1007/BF03178640 |
2009 Journal Article THE DEVELOPMENT OF A MONTE CARLO SYSTEM TO VERIFY RADIOTHERAPY TREATMENT DOSE CALCULATIONSCrowe, S., Kairn, T. and Fielding, A. (2009). THE DEVELOPMENT OF A MONTE CARLO SYSTEM TO VERIFY RADIOTHERAPY TREATMENT DOSE CALCULATIONS. Radiotherapy and Oncology, 92, S71. doi: 10.1016/s0167-8140(12)72778-0 |
2009 Journal Article Internal calibration of gel dosimeters: A feasibility studyTrapp, J. V., Kairn, T., Crowe, S. and Fielding, A. (2009). Internal calibration of gel dosimeters: A feasibility study. Journal of Physics: Conference Series, 164 012014. doi: 10.1088/1742-6596/164/1/012014 |