|
2010 Conference Publication A modelling study of a hybrid loop-strip coil structure for multichannel transceive breast array coilLi, Y., Liu, F., Jin, J., Weber, E., Li, B., Wang, H. and Crozier, S. (2010). A modelling study of a hybrid loop-strip coil structure for multichannel transceive breast array coil. ISMRM, Stockholm, Sweden, 1-7 May, 2010. New York, NY, U.S.A.: International Society of Magnetic Resonance in Medicine. |
|
2010 Conference Publication A stripline-like coil element structure for high field phased array coils and its application for a 8-channel 9.4T small animal transceive arrayLi. Y., Weber, E., Li, J., Liu, F., Schneider, J., Ohrel, S., Junge, S., Ullmann, P., Wick, M. and Crozier, S. (2010). A stripline-like coil element structure for high field phased array coils and its application for a 8-channel 9.4T small animal transceive array. ISMRM, Stockholm, Sweden, 1-7 May, 2010. New York, NY, U.S.A.: International Society of Magnetic Resonance in Medicine. |
|
2010 Conference Publication Maxwell's equation tailored reverse method of obtaining coil sensitivity for parallel MRIJin, J., Liu, F., Weber, E. and Crozier, S. (2010). Maxwell's equation tailored reverse method of obtaining coil sensitivity for parallel MRI. ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden, 1-7 May 2010. United States: |
|
2010 Conference Publication On the reduction of the transmit B1 non-uniformity and SAR using a single-element rotating RF coilLiu, Feng, Weber, Ewald, Trakic, Adnan, Wang, Hua and Crozier, Stuart (2010). On the reduction of the transmit B1 non-uniformity and SAR using a single-element rotating RF coil. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 2010. Berkeley, CA, U.S.A.: Curran Associates. |
|
2009 Journal Article Image reconstructions with the rotating RF coilTrakic, A., Wang, H., Weber, E., Li, B. K., Poole, M., Liu, F. and Crozier, S. (2009). Image reconstructions with the rotating RF coil. Journal of Magnetic Resonance, 201 (2), 186-198. doi: 10.1016/j.jmr.2009.09.009 |
|
2009 Journal Article Hybrid numerical techniques for the modelling of radiofrequency coils in MRILi, Bing Keong, Liu, Feng, Weber, Ewald and Crozier, Stuart (2009). Hybrid numerical techniques for the modelling of radiofrequency coils in MRI. NMR in Biomedicine, 22 (9), 937-951. doi: 10.1002/nbm.1344 |
|
2009 Journal Article Inverse design of a phased-array coil for breast magnetic resonance imagingLi, Yu, Liu, Feng, Weber, Ewald, Li, Bing Keong and Crozier, Stuart (2009). Inverse design of a phased-array coil for breast magnetic resonance imaging. Concepts in Magnetic Resonance Part B- Magnetic Resonance Engineering, 35B (4), 221-231. doi: 10.1002/cmr.b.20145 |
|
2009 Journal Article A rapidly rotating RF coil for MRITrakic, Adnan, Li, Bing Keong, Weber, Ewald, Wang, Hua, Wilson, Stephen and Crozier, Stuart (2009). A rapidly rotating RF coil for MRI. Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 35B (2), 59-66. doi: 10.1002/cmr.b.20136 |
|
2009 Journal Article Reverse-engineering of gradient coil designs based on experimentally measured magnetic fields and approximate knowledge of coil geometry-application in exposure evaluationsLiu, Feng, Trakic, Adnan, Sanchez Lopez, Hector, Wei, Qing, Fuentes, Miguel, Weber, Ewald and Crozier, Stuart (2009). Reverse-engineering of gradient coil designs based on experimentally measured magnetic fields and approximate knowledge of coil geometry-application in exposure evaluations. Concepts in Magnetic Resonance Part B- Magnetic Resonance Engineering, 35B (1), 32-43. doi: 10.1002/cmr.b.20129 |
|
2009 Conference Publication MRI with a rapidly rotating coilTrakic, Adnan, Weber, Ewald, Li, Bing Keong, Wang, Hua and Crozier, Stuart (2009). MRI with a rapidly rotating coil. 17th ISMRM Scientific Meeting & Exhibition, Honolulu, Hawaii, 18-24 April 2009. USA: International Society for Magnetic Resonance in Medicine. |
|
2009 Conference Publication A mechanically rotating RF transceive system and method for applications in magnetic resonanceTrakic, Adnan, Li, Bing Keong, Weber, Ewald, Liu, Feng, Wilson, Stephen and Crozier, Stuart (2009). A mechanically rotating RF transceive system and method for applications in magnetic resonance. 17th ISMRM Scientific Meeting & Exhibition, Honolulu, Hawaii, 18-24 April 2009. USA: International Society for Magnetic Resonance in Medicine. |
|
2009 Conference Publication An inverse method for the design of RF array coils with a sparse structure and its application for breast imagingLi, Yu, Liu, Feng, Weber, Ewald, Li, Bing Keong and Crozier, Stuart (2009). An inverse method for the design of RF array coils with a sparse structure and its application for breast imaging. 17th ISMRM Scientific Meeting & Exhibition, Honolulu, Hawaii, 18-24 April 2009. USA: International Society for Magnetic Resonance in Medicine. |
|
2008 Journal Article Passive Shim Design and a Shimming Approach for Biplanar Permanent Magnetic Resonance Imaging MagnetsSanchez Lopez, H., Liu, F., Weber, E. and Crozier, S. (2008). Passive Shim Design and a Shimming Approach for Biplanar Permanent Magnetic Resonance Imaging Magnets. IEEE Transactions On Magnetics, 44 (3) 4455704, 394-402. doi: 10.1109/TMAG.2007.914770 |
|
2008 Conference Publication Lowering the imager significantly reduces the field exposure of MRI occupational workersTrakic, A., Wang, H., Sanchez Lopez, H., Weber, E. and Crozier, S. (2008). Lowering the imager significantly reduces the field exposure of MRI occupational workers. The International Society for Magnetic Resonance in Medicine's 16th Scientific Meeting and Exhibition, Toronto, Ontario, Canada, 3-9 May 2008. USA: International Society for Magnetic Resonance in Medicine. |
|
2008 Conference Publication A novel method for passive shim design: ILopez, Hector Sanchez, Liu, Feng, Weber, Ewald and Crozier, Stuart (2008). A novel method for passive shim design: I. Progress In Electromagnetics Research Symposium (PIERS), Hangzhou, China, 24-28 March 2008. The Electromagnetics Academy. |
|
2008 Conference Publication Development of a Multi-Channel Transmit Extension for a Broadband RF-Electronics and its Evaluation on a 9.4 T Animal Scanner with 8 Transmit ChannelsUllmann, P., Erber, G., Eckert, T., Freitag, P., Gotzelmann, G, Heidenreich, M, Heinen, U., Junge, S., Lendi, P., Odermatt, B., Post, H., Rommel, J., Schwilch, A., Uhrig, W., Velten, R., Wark, U., Weber, E. and Ruhm, W. (2008). Development of a Multi-Channel Transmit Extension for a Broadband RF-Electronics and its Evaluation on a 9.4 T Animal Scanner with 8 Transmit Channels. The International Society for Magnetic Resonance in Medicine's 16th Scientific Meeting and Exhibition, Toronto, Ontario, Canada, 3-9 May 2008. USA: International Society for Magnetic Resonance in Medicine. |
|
2008 Conference Publication A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRILi, Y., Wang, H., Liu, F., Li, B.K., Shou, G., Weber, E. and Crozier, S. (2008). A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRI. 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, Canada, 20-24 August 2008. Piscataway, NJ, United States: IEEE. doi: 10.1109/IEMBS.2008.4649184 |
|
2008 Conference Publication A novel 8-channel transceive volume-array for a 9.4T animal scannerWeber, E., Li, B.K, Liu, F, Li, Y, Ullmann, P., Sanchez Lopez, H. and Crozier, S. (2008). A novel 8-channel transceive volume-array for a 9.4T animal scanner. International Society for Magnetic Resonance in Medicine - 16th Scientific Meeting and Exhibition, Toronto, Canada, 3 - 9 May, 2008. US: ISMRM. |
|
2008 Journal Article Parallel Solvers for Finite-Difference Modeling of Large-Scale, High-Resolution Electromagnetic Problems in MRIWang, H., Trakic, A., Liu, F., Li, B.K., Weber, E. and Crozier, S. (2008). Parallel Solvers for Finite-Difference Modeling of Large-Scale, High-Resolution Electromagnetic Problems in MRI. International Journal of Antennas and Propagation, 2008 (Article ID 259703), 1-12. doi: 10.1155/2008/259703 |
|
2008 Conference Publication A new shimming approach using the Equivalent Magnetizing Current (EMC) MethodSanchez Lopez, H., Liu, F., Trakic, A., Weber, E. and Crozier, S. (2008). A new shimming approach using the Equivalent Magnetizing Current (EMC) Method. The International Society for Magnetic Resonance in Medicine, Toronto, Ontario, Canada, 3-9 May 2008. USA: International Society for Magnetic Resonance in Medicine. |