Skip to menu Skip to content Skip to footer

2010

Journal Article

An electromagnetic reverse method of coil sensitivity mapping for parallel MRI - Theoretical framework

Jin, Jin, Liu, Feng, Weber, Ewald, Li, Yu and Crozier, Stuart (2010). An electromagnetic reverse method of coil sensitivity mapping for parallel MRI - Theoretical framework. Journal of Magnetic Resonance, 207 (1), 59-68. doi: 10.1016/j.jmr.2010.08.009

An electromagnetic reverse method of coil sensitivity mapping for parallel MRI - Theoretical framework

2010

Journal Article

Calculating temperature distributions for gradient coils

While, Peter T., Forbes, Lawrence K. and Crozier, Stuart (2010). Calculating temperature distributions for gradient coils. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 37B (3), 146-159. doi: 10.1002/cmr.b.20163

Calculating temperature distributions for gradient coils

2010

Journal Article

Tikhonov regularization approach for acoustic noise reduction in an asymmetric, self-shielded MRI gradient coil

Jackson, James M., Brideson, Michael A., Forbes, Larry K. and Crozier, Stuart (2010). Tikhonov regularization approach for acoustic noise reduction in an asymmetric, self-shielded MRI gradient coil. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 37B (3), 167-179. doi: 10.1002/cmr.b.20166

Tikhonov regularization approach for acoustic noise reduction in an asymmetric, self-shielded MRI gradient coil

2010

Journal Article

Evaluating passively shielded gradient coil configurations for optimal eddy current compensation

Sanchez Lopez, Hector, Poole, Michael and Crozier, Stuart (2010). Evaluating passively shielded gradient coil configurations for optimal eddy current compensation. Journal of Physics D - Applied Physics, 43 (19) 195005, 1-13. doi: 10.1088/0022-3727/43/19/195005

Evaluating passively shielded gradient coil configurations for optimal eddy current compensation

2010

Journal Article

MRI coil design using boundary-element method with regularization technique: A numerical calculation study

Shou, Guofa, Xia, Ling, Liu, Feng, Zhu, Minhua, Li, Yu and Crozier, Stuart (2010). MRI coil design using boundary-element method with regularization technique: A numerical calculation study. IEEE Transactions on Magnetics, 46 (4) 5352342, 1052-1059. doi: 10.1109/TMAG.2009.2037753

MRI coil design using boundary-element method with regularization technique: A numerical calculation study

2010

Journal Article

Minimax current density coil design

Poole, Michael, Weiss, Pierre, Sanchez Lopez, Hector, Ng, Michael and Crozier, Stuart (2010). Minimax current density coil design. Journal of Physics D: Applied Physics, 43 (9) 095001, 095001-1-095001-14. doi: 10.1088/0022-3727/43/9/095001

Minimax current density coil design

2010

Journal Article

Designing gradient coils with reduced hot spot temperatures

While, Peter T., Forbes, Larry K. and Crozier, Stuart (2010). Designing gradient coils with reduced hot spot temperatures. Journal of Magnetic Resonance, 203 (1), 91-99. doi: 10.1016/j.jmr.2009.12.004

Designing gradient coils with reduced hot spot temperatures

2010

Journal Article

Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means

Gal, Yaniv, Mehnert, Andrew J. H., Bradley, Andrew P., McMahon, Kerry, Kennedy, Dominic and Crozier, Stuart (2010). Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means. IEEE Transactions on Medical Imaging, 29 (2) 5165030, 302-310. doi: 10.1109/TMI.2009.2026575

Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means

2010

Conference Publication

GPU accelerated FDTD solver and its application in MRI

Chi, Jieru, Liu, Feng, Jin, Jin, Mason, D.G. and Crozier, S. (2010). GPU accelerated FDTD solver and its application in MRI. 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC'10, Buenos Aires, Argentina, 31 August-4 September, 2010. Piscataway, NJ, U.S.A.: IEEE Engineering in Medicine and Biology Society : IEEE Consumer Electronics Society. doi: 10.1109/IEMBS.2010.5627497

GPU accelerated FDTD solver and its application in MRI

2010

Conference Publication

A modelling study of a hybrid loop-strip coil structure for multichannel transceive breast array coil

Li, Y., Liu, F., Jin, J., Weber, E., Li, B., Wang, H. and Crozier, S. (2010). A modelling study of a hybrid loop-strip coil structure for multichannel transceive breast array coil. ISMRM, Stockholm, Sweden, 1-7 May, 2010. New York, NY, U.S.A.: International Society of Magnetic Resonance in Medicine.

A modelling study of a hybrid loop-strip coil structure for multichannel transceive breast array coil

2010

Conference Publication

Using shape optimization to linearise the eddy current field

Sanchez, Hector, Michael Poole and Crozier, Stuart (2010). Using shape optimization to linearise the eddy current field. ISMRM, Stockholm, Sweden, 1-7 May 2010. New York, NY, U.S.A.: International Society of Magnetic Resonance in Medicine.

Using shape optimization to linearise the eddy current field

2010

Conference Publication

Temperature characteristics of gradient coils with minimax current density

Poole, Michael Stephen, Weiss, Pierre, Sanchez Lopez, Hector, Ng, Michael and Crozier, Stuart (2010). Temperature characteristics of gradient coils with minimax current density. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 210. Berkeley, CA, U.S.A.: Curran Associates.

Temperature characteristics of gradient coils with minimax current density

2010

Conference Publication

An orthogonality based RF decoupling method

Wang, Hua, Li, Joe, Trakic, Adnan, Engstrom, Craig M., Li, Yu and Crozier, Stuart (2010). An orthogonality based RF decoupling method. ISMRM, Stockholm, Sweden, 1-7 May, 2010. New York, NY, U.S.A.: International Society of Magnetic Resonance in Medicine.

An orthogonality based RF decoupling method

2010

Conference Publication

Maxwell's equation tailored reverse method of obtaining coil sensitivity for parallel MRI

Jin, J., Liu, F., Weber, E. and Crozier, S. (2010). Maxwell's equation tailored reverse method of obtaining coil sensitivity for parallel MRI. ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden, 1-7 May 2010. United States:

Maxwell's equation tailored reverse method of obtaining coil sensitivity for parallel MRI

2010

Conference Publication

Symmetric diffeomorphic normalisation of fibre orientation distributions

Raffelt, David A., Tournier, J.- Donald, Fripp, Jurgen, Connelly, Alan, Crozier, Stuart and Salvado, Oliver (2010). Symmetric diffeomorphic normalisation of fibre orientation distributions. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 2010. Berkeley, CA, U.S.A.: Curran Associates.

Symmetric diffeomorphic normalisation of fibre orientation distributions

2010

Conference Publication

A temperature distribution model for gradient coils

While, P., Forbes, L. and Crozier, S. (2010). A temperature distribution model for gradient coils. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 2010. Berkeley, CA, U.S.A.: Curran Associates.

A temperature distribution model for gradient coils

2010

Conference Publication

Comparison and analysis of nonlinear algorithms for compressed sensing in MRI

Yu, Yeyang, Hong, Mingjian, Liu, Feng, Wang, Hua and Crozier, Stuart (2010). Comparison and analysis of nonlinear algorithms for compressed sensing in MRI. 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC), Buenos Aires, Argentina, 31 August - 4 September, 2010. United States: IEEE (Institute for Electrical and Electronic Engineers). doi: 10.1109/IEMBS.2010.5627897

Comparison and analysis of nonlinear algorithms for compressed sensing in MRI

2010

Conference Publication

On the reduction of the transmit B1 non-uniformity and SAR using a single-element rotating RF coil

Liu, Feng, Weber, Ewald, Trakic, Adnan, Wang, Hua and Crozier, Stuart (2010). On the reduction of the transmit B1 non-uniformity and SAR using a single-element rotating RF coil. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 2010. Berkeley, CA, U.S.A.: Curran Associates.

On the reduction of the transmit B1 non-uniformity and SAR using a single-element rotating RF coil

2010

Conference Publication

Can we re-design the gradient coil to make the eddy current field match the primary gradient field?

Sanchez Lopez, Hector, Michael Poole, Trakic, Adnan and Crozier, Stuart (2010). Can we re-design the gradient coil to make the eddy current field match the primary gradient field?. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 2010. Berkeley, CA, U.S.A.: Curran Associates.

Can we re-design the gradient coil to make the eddy current field match the primary gradient field?

2010

Conference Publication

A reduced order finite element algorithm for surgical simulation

Taylor, Zeike A ., Ourselin, Sebastien and Crozier, Stuart (2010). A reduced order finite element algorithm for surgical simulation. 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC'10), Buenos Aires, Argentina, 31 August-4 September, 2010. Piscataway, NJ, U.S.A.: IEEE Engineering in Medicine and Biology Society : IEEE Consumer Electronics Society. doi: 10.1109/IEMBS.2010.5627720

A reduced order finite element algorithm for surgical simulation