2010

Journal Article

3D gradient coil design for open MRI systems

While, Peter T., Forbes, Lawrence K. and Crozier, Stuart (2010). 3D gradient coil design for open MRI systems. Journal of Magnetic Resonance, 207 (1), 124-133. doi: 10.1016/j.jmr.2010.08.017

3D gradient coil design for open MRI systems

2010

Journal Article

Calculating temperature distributions for gradient coils

While, Peter T., Forbes, Lawrence K. and Crozier, Stuart (2010). Calculating temperature distributions for gradient coils. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 37B (3), 146-159. doi: 10.1002/cmr.b.20163

Calculating temperature distributions for gradient coils

2010

Journal Article

Tikhonov regularization approach for acoustic noise reduction in an asymmetric, self-shielded MRI gradient coil

Jackson, James M., Brideson, Michael A., Forbes, Larry K. and Crozier, Stuart (2010). Tikhonov regularization approach for acoustic noise reduction in an asymmetric, self-shielded MRI gradient coil. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 37B (3), 167-179. doi: 10.1002/cmr.b.20166

Tikhonov regularization approach for acoustic noise reduction in an asymmetric, self-shielded MRI gradient coil

2010

Journal Article

Evaluating passively shielded gradient coil configurations for optimal eddy current compensation

Sanchez Lopez, Hector, Poole, Michael and Crozier, Stuart (2010). Evaluating passively shielded gradient coil configurations for optimal eddy current compensation. Journal of Physics D - Applied Physics, 43 (19) 195005, 1-13. doi: 10.1088/0022-3727/43/19/195005

Evaluating passively shielded gradient coil configurations for optimal eddy current compensation

2010

Journal Article

MRI coil design using boundary-element method with regularization technique: A numerical calculation study

Shou, Guofa, Xia, Ling, Liu, Feng, Zhu, Minhua, Li, Yu and Crozier, Stuart (2010). MRI coil design using boundary-element method with regularization technique: A numerical calculation study. IEEE Transactions on Magnetics, 46 (4) 5352342, 1052-1059. doi: 10.1109/TMAG.2009.2037753

MRI coil design using boundary-element method with regularization technique: A numerical calculation study

2010

Journal Article

Minimax current density coil design

Poole, Michael, Weiss, Pierre, Sanchez Lopez, Hector, Ng, Michael and Crozier, Stuart (2010). Minimax current density coil design. Journal of Physics D: Applied Physics, 43 (9) 095001, 095001-1-095001-14. doi: 10.1088/0022-3727/43/9/095001

Minimax current density coil design

2010

Journal Article

Designing gradient coils with reduced hot spot temperatures

While, Peter T., Forbes, Larry K. and Crozier, Stuart (2010). Designing gradient coils with reduced hot spot temperatures. Journal of Magnetic Resonance, 203 (1), 91-99. doi: 10.1016/j.jmr.2009.12.004

Designing gradient coils with reduced hot spot temperatures

2010

Journal Article

Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means

Gal, Yaniv, Mehnert, Andrew J. H., Bradley, Andrew P., McMahon, Kerry, Kennedy, Dominic and Crozier, Stuart (2010). Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means. IEEE Transactions on Medical Imaging, 29 (2) 5165030, 302-310. doi: 10.1109/TMI.2009.2026575

Denoising of dynamic contrast-enhanced MR images using dynamic nonlocal means

2010

Journal Article

Computational modelling of blood-flow-induced changes in blood electrical conductivity and its contribution to the impedance cardiogram

Trakic, A., Akhand, M., Wang, H., Mason, D., Liu, F., Wilson, S. and Crozier, S. (2010). Computational modelling of blood-flow-induced changes in blood electrical conductivity and its contribution to the impedance cardiogram. Physiological Measurement, 31 (1), 13-33. doi: 10.1088/0967-3334/31/1/002

Computational modelling of blood-flow-induced changes in blood electrical conductivity and its contribution to the impedance cardiogram

2010

Conference Publication

GPU Accelerated FDTD Solver and Its Application in B1-Shimming

Chi, J., Liu, F., Weber, Ewald, Li, Y., Wei, R., Xu,W., Trakic, A, Wang, H. and Crozier, S (2010). GPU Accelerated FDTD Solver and Its Application in B1-Shimming. ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden, 1-7 May 2010.

GPU Accelerated FDTD Solver and Its Application in B1-Shimming

2010

Conference Publication

Minimax current density coil design

Poole, Michael, Weiss, P., Sanchez Lopez, Hector, Ng, M and Crozier, Stuart (2010). Minimax current density coil design. ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden, 1-7 May. Berkeley, Calif.: International Society for Magnetic Resonance in Medicine.

Minimax current density coil design

2010

Conference Publication

Designing 3D Gradient Coils for Open MRI Systems

While, P., Forbes, L. and Crozier, Stuart (2010). Designing 3D Gradient Coils for Open MRI Systems. Joint Annual Meeting ISMRM-ESMRMB 2010, Stockholm, Sweden, 1-7 May 2010. Berkeley, Calif.: International Society for Magnetic Resonance in Medicine.

Designing 3D Gradient Coils for Open MRI Systems

2010

Conference Publication

Two non-linear parametric models of contrast enhancement for DCE-MRI of the breast amenable to fitting using linear least squares

Mehnert, Andrew, Wildermoth, Michael, Crozier, Stuart, Bengtsson, Ewert and Kennedy, Dominic (2010). Two non-linear parametric models of contrast enhancement for DCE-MRI of the breast amenable to fitting using linear least squares. Digital Image Computing: Techniques and Applications (DICTA), Sydney , Australia, 1-3 December 2010. Los Alamitos, U.S.A.: IEEE. doi: 10.1109/DICTA.2010.8

Two non-linear parametric models of contrast enhancement for DCE-MRI of the breast amenable to fitting using linear least squares

2010

Conference Publication

Joint factor and kinetic analysis of dynamic FDOPA PET scans of brain cancer patients

Dowson, N., Bourgeat, P., Rose, S., Daglish, M., Smith, J., Fay, M., Coulthard A., Winter, C., MacFarlane, D., Thomas, P., Crozier, S. and Salvado, O. (2010). Joint factor and kinetic analysis of dynamic FDOPA PET scans of brain cancer patients. 13th International Conference on Medical Image Computing and Computer-Assisted Intervention, MICCAI 2010, Beijing, China, 20 - 24 September 2010. Heidelberg, Germany: Springer. doi: 10.1007/978-3-642-15745-5_23

Joint factor and kinetic analysis of dynamic FDOPA PET scans of brain cancer patients

2010

Conference Publication

An improved cylindrical FDTD method and its application to field-tissue interaction study in MRI

Chi, Jieru, Liu, Feng, Xia, Ling, Shao, Tingting, Mason, David and Crozier, Stuart (2010). An improved cylindrical FDTD method and its application to field-tissue interaction study in MRI. 32nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC'10), Buenos Aires, Argentina, 31 August-4 September, 2010. Piscataway, NJ, U.S.A.: IEEE Engineering in Medicine and Biology Society : IEEE Consumer Electronics Society. doi: 10.1109/IEMBS.2010.5627189

An improved cylindrical FDTD method and its application to field-tissue interaction study in MRI

2010

Conference Publication

A 7T ‘Capless’ Transceive Breast Coil

Li, Bing Keong, Wang, Hua, Weber, Ewald, Li, Yu, Trakic, Adnan, Lee, Daniel James, Farhat, Sedig, Glover, Paul, Bowtell, Richard and Crozier, Stuart (2010). A 7T ‘Capless’ Transceive Breast Coil. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 2010. Berkeley, CA, U.S.A.: Curran Associates.

A 7T ‘Capless’ Transceive Breast Coil

2010

Conference Publication

Improved delineation of brain tumour margins using whole-brain track-density mapping

Rose, S., Crozier, S., Bourgeat, P., Dowson, N., Salvado, O., Raniga, P., Pannek, K., Coulthard, A., Fay, M., Thomas, P. and MacFarlane, D. (2010). Improved delineation of brain tumour margins using whole-brain track-density mapping. ISMRM-ESMRMB Joint Annual Meeting 2010: Clinical Needs and Technological Solutions, Stockholm, Sweden, 1-7 May 2010. New York, USA: International Society of Magnetic Resonance in Medicine.

Improved delineation of brain tumour margins using whole-brain track-density mapping

2010

Conference Publication

A stripline-like coil element structure for high field phased array coils and its application for a 8-channel 9.4T small animal transceive array

Li. Y., Weber, E., Li, J., Liu, F., Schneider, J., Ohrel, S., Junge, S., Ullmann, P., Wick, M. and Crozier, S. (2010). A stripline-like coil element structure for high field phased array coils and its application for a 8-channel 9.4T small animal transceive array. ISMRM, Stockholm, Sweden, 1-7 May, 2010. New York, NY, U.S.A.: International Society of Magnetic Resonance in Medicine.

A stripline-like coil element structure for high field phased array coils and its application for a 8-channel 9.4T small animal transceive array

2010

Conference Publication

Eigenmode analysis of Eddy Currents and Eigenmode Coil Design

Poole, Michael, Sanchez Lopez, Hector and Crozier, Stuart (2010). Eigenmode analysis of Eddy Currents and Eigenmode Coil Design. ISMRM-ESMRMB Joint Annual Meeting 2010, Stockholm, Sweden, 1-7 May. Berkeley, CA, United States: International Society for Magnetic Resonance in Medicine.

Eigenmode analysis of Eddy Currents and Eigenmode Coil Design

2010

Conference Publication

Time Division Multiplexed - Sensitivity Encoding (TDM-SENSE) with a mechanically rotating RF coil

Trakic, A., Wang, H., Weber, E., Li, B., Poole, M., Liu, F. and Crozier, S. (2010). Time Division Multiplexed - Sensitivity Encoding (TDM-SENSE) with a mechanically rotating RF coil. ISMRM, Stockholm, Sweden, 1-7 May 2010. New York, NY, U.S.A.: International Society of Magnetic Resonance in Medicine.

Time Division Multiplexed - Sensitivity Encoding (TDM-SENSE) with a mechanically rotating RF coil