Skip to menu Skip to content Skip to footer

2008

Conference Publication

Hybrid imaging method for early breast cancer dtection

Abbosh, A. M. and Crozier, S. (2008). Hybrid imaging method for early breast cancer dtection. Cairo International Biomedical Engineering Conference, 2008, Cairo, Egypt, 18-20 December 2008. Piscataway, N.J, U.S.A.: IEEE. doi: 10.1109/CIBEC.2008.4786049

Hybrid imaging method for early breast cancer dtection

2008

Conference Publication

A comparison of DCT and DWT block based watermarking on medical image quality

Dowling, Jason, Planitz, Birgit M., Maeder, Anthony J., Du, Jiang, Pham, Binh, Boyd, Colin, Chen, Shaokang, Bradley, Andrew P. and Crozier, Stuart (2008). A comparison of DCT and DWT block based watermarking on medical image quality. 6th International Workshop on Digital Watermarking, Guangzhou, China, 3-5 December 2007. Heidelberg, Germany: Springer. doi: 10.1007/978-3-540-92238-4_35

A comparison of DCT and DWT block based watermarking on medical image quality

2008

Conference Publication

An efficient BiCGstab solved impedance method for induced field evaluation with a hyperthermia applicator

Wang, H., Liu, F., Xia, L., Li, B. K. and Crozier, S. (2008). An efficient BiCGstab solved impedance method for induced field evaluation with a hyperthermia applicator. 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, Canada, 20-24 August 2008. Piscataway, NJ, United States: IEEE. doi: 10.1109/IEMBS.2008.4650492

An efficient BiCGstab solved impedance method for induced field evaluation with a hyperthermia applicator

2008

Conference Publication

A novel method for passive shim design: I

Lopez, Hector Sanchez, Liu, Feng, Weber, Ewald and Crozier, Stuart (2008). A novel method for passive shim design: I. Progress In Electromagnetics Research Symposium (PIERS), Hangzhou, China, 24-28 March 2008. The Electromagnetics Academy.

A novel method for passive shim design: I

2008

Conference Publication

A new denoising method for dynamic contrast-enhanced MRI

Gal, Yaniv, Mehnert, Andrew, Bradley, Andrew, McMahon, Kerry, Kennedy, Dominic and Crozier, Stuart (2008). A new denoising method for dynamic contrast-enhanced MRI. 30th Annual International IEEE EMBS Conference, Vancouver, B.C.,Canada, 20-24 August 2008. Piscataway, NJ, U.S.A.: IEEE - Institute of Electrical Electronics Engineers Inc.. doi: 10.1109/IEMBS.2008.4649286

A new denoising method for dynamic contrast-enhanced MRI

2008

Journal Article

Parallel Solvers for Finite-Difference Modeling of Large-Scale, High-Resolution Electromagnetic Problems in MRI

Wang, H., Trakic, A., Liu, F., Li, B.K., Weber, E. and Crozier, S. (2008). Parallel Solvers for Finite-Difference Modeling of Large-Scale, High-Resolution Electromagnetic Problems in MRI. International Journal of Antennas and Propagation, 2008 (Article ID 259703) 259703, 1-12. doi: 10.1155/2008/259703

Parallel Solvers for Finite-Difference Modeling of Large-Scale, High-Resolution Electromagnetic Problems in MRI

2008

Conference Publication

Edge intensity normalization as a bias field correction during balloon snake segmentation of breast MRI

Hill, A., Mehnert, A. and Crozier, S. (2008). Edge intensity normalization as a bias field correction during balloon snake segmentation of breast MRI. Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, Canada, 20-24 August 2008. Piscataway, NJ, United States: IEEE. doi: 10.1109/IEMBS.2008.4649844

Edge intensity normalization as a bias field correction during balloon snake segmentation of breast MRI

2008

Conference Publication

A new method in accelerating PROPELLER MRI

Li, B. K., D'Arcy, M., Weber, E. and Crozier, S. (2008). A new method in accelerating PROPELLER MRI. 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2008 (EMBS 2008), Vancouver, Canada, 20-25 August 2008. Piscataway, NJ, U.S.A.: IEEE - Institute of Electrical Electronics Engineers Inc.. doi: 10.1109/IEMBS.2008.4649492

A new method in accelerating PROPELLER MRI

2008

Conference Publication

The Equivalent Magnetizing Current (EMC) method for biplanar active and passive shim design

Sanchez Lopez, H., Liu, F., Trakic, A., Weber, E. and Crozier, S. (2008). The Equivalent Magnetizing Current (EMC) method for biplanar active and passive shim design. International Society for Magnetic Resonance in Medicine, Toronto, Ontario, Canada, 3-9 May 2008. USA: International Society for Magnetic Resonance in Medicine.

The Equivalent Magnetizing Current (EMC) method for biplanar active and passive shim design

2008

Conference Publication

EMF generated by the static magnetic field

Liu, Feng, Wang, Hua, Trakic, Adnan and Crozier, Stuart (2008). EMF generated by the static magnetic field. international Society for Magnetic Resonance in Medicine Workshop on MR safety, Lisbon, Portugal, 13-14 July, 2008.

EMF generated by the static magnetic field

2008

Conference Publication

A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRI

Li, Y., Wang, H., Liu, F., Li, B.K., Shou, G., Weber, E. and Crozier, S. (2008). A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRI. 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, Canada, 20-24 August 2008. Piscataway, NJ, United States: IEEE. doi: 10.1109/IEMBS.2008.4649184

A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRI

2008

Conference Publication

Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region

Jurcak,V., Fripp, J., Engstrom, C., Walker, D., Salvado, O., Ourselin, S. and Crozier, S. (2008). Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region. 5th IEEE International Symposium on Biomedical Imaging - From Nano to Macro, Paris, France, 14-17 May 2008. New York, USA: IEEE. doi: 10.1109/ISBI.2008.4540945

Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region

2008

Journal Article

Minimizing the induced fields in MRI Occupational Workers by Lowering the Imager

Trakic, A., Wang, H., Liu, F., Sanchez Lopez, H., Weber, E. and Crozier, S. (2008). Minimizing the induced fields in MRI Occupational Workers by Lowering the Imager. Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 33B (1), 39-54. doi: 10.1002/cmr.b.20102

Minimizing the induced fields in MRI Occupational Workers by Lowering the Imager

2007

Journal Article

On the accurate modeling of a complex antenna for breast tumor detection using a hybrid MOM/FDTD approach

Padhi, Shantanu, Liu, Feng, Li, Bing Keong, Shuley, Nicholas and Crozier, Stuart (2007). On the accurate modeling of a complex antenna for breast tumor detection using a hybrid MOM/FDTD approach. Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference, 6637-6640.

On the accurate modeling of a complex antenna for breast tumor detection using a hybrid MOM/FDTD approach

2007

Journal Article

An analytical approach to the design of quiet cylindrical asymmetric gradient coils in MRI

Forbes, Lawrence K, Brideson, Michael A, Crozier, Stuart and While, Peter T (2007). An analytical approach to the design of quiet cylindrical asymmetric gradient coils in MRI. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 31B (4), 218-236. doi: 10.1002/cmr.b.20095

An analytical approach to the design of quiet cylindrical asymmetric gradient coils in MRI

2007

Journal Article

Segmentation of the bones in MRIs of the knee using phase, magnitude, and shape information

Fripp, Jurgen, Bourgeat, Pierrick, Crozier, Stuart and Ourselin, Sebastien (2007). Segmentation of the bones in MRIs of the knee using phase, magnitude, and shape information. Academic Radiology, 14 (10), 1201-1208. doi: 10.1016/j.acra.2007.06.021

Segmentation of the bones in MRIs of the knee using phase, magnitude, and shape information

2007

Journal Article

The role of quadratus lumborum asymmetry in the occurrence of lesions in the lumbar vertebrae of cricket fast bowlers

de Visser, Hans, Adam, Clayton J., Crozier, Stuart and Pearcy, Mark J. (2007). The role of quadratus lumborum asymmetry in the occurrence of lesions in the lumbar vertebrae of cricket fast bowlers. Medical Engineering & Physics, 29 (8), 877-885. doi: 10.1016/j.medengphy.2006.09.010

The role of quadratus lumborum asymmetry in the occurrence of lesions in the lumbar vertebrae of cricket fast bowlers

2007

Conference Publication

Three-dimensional gradient coil structures for magnetic resonance imaging designed using-fuzzy membership functions

Sanchez, H., Liu, F., Trakic, A., Weber, E. and Crozier, S. (2007). Three-dimensional gradient coil structures for magnetic resonance imaging designed using-fuzzy membership functions. New York: I.E.E.E.. doi: 10.1109/TMAG.2007.902065

Three-dimensional gradient coil structures for magnetic resonance imaging designed using-fuzzy membership functions

2007

Journal Article

An MRI-dedicated parallel FDTD scheme

Wang, Hua, Trakic, Adnan, Xia, Ling, Liu, Feng and Crozier, Stuart (2007). An MRI-dedicated parallel FDTD scheme. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 31B (3), 147-161. doi: 10.1002/cmr.b.20092

An MRI-dedicated parallel FDTD scheme

2007

Journal Article

Longitudinal gradient coil optimization in the presence of transient eddy currents

Trakic, Adnan, Liu, Feng, Sanchez Lopez, Hector, Wang, Hua and Crozier, Stuart (2007). Longitudinal gradient coil optimization in the presence of transient eddy currents. Magnetic Resonance in Medicine, 57 (6), 1119-1130. doi: 10.1002/mrm.21243

Longitudinal gradient coil optimization in the presence of transient eddy currents