Skip to menu Skip to content Skip to footer

2008

Conference Publication

A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRI

Li, Y., Wang, H., Liu, F., Li, B.K., Shou, G., Weber, E. and Crozier, S. (2008). A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRI. 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Vancouver, Canada, 20-24 August 2008. Piscataway, NJ, United States: IEEE. doi: 10.1109/IEMBS.2008.4649184

A comparison study of regularization techniques on the theoretical design of phased array RF coils in MRI

2008

Conference Publication

Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region

Jurcak,V., Fripp, J., Engstrom, C., Walker, D., Salvado, O., Ourselin, S. and Crozier, S. (2008). Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region. 5th IEEE International Symposium on Biomedical Imaging - From Nano to Macro, Paris, France, 14-17 May 2008. New York, USA: IEEE. doi: 10.1109/ISBI.2008.4540945

Atlas based automated segmentation of the quadratus lumborum muscle using non-rigid registration on magnetic resonance images of the thoracolumbar region

2008

Journal Article

Minimizing the induced fields in MRI Occupational Workers by Lowering the Imager

Trakic, A., Wang, H., Liu, F., Sanchez Lopez, H., Weber, E. and Crozier, S. (2008). Minimizing the induced fields in MRI Occupational Workers by Lowering the Imager. Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 33B (1), 39-54. doi: 10.1002/cmr.b.20102

Minimizing the induced fields in MRI Occupational Workers by Lowering the Imager

2008

Journal Article

Computing lorentz forces generated by gradient coils in an open MRI system

Brideson, M. A., Jackson, J., Forbes, L. K. and Crozier, S. (2008). Computing lorentz forces generated by gradient coils in an open MRI system. ANZIAM Journal, 49, C423-C438.

Computing lorentz forces generated by gradient coils in an open MRI system

2008

Conference Publication

A simple model for electromagnetic scattering due to breast tumour

Abbosh, A., Bialkowski, M. E. and Crozier, S. (2008). A simple model for electromagnetic scattering due to breast tumour. 2008 IEEE International Symposium on Antennas and Propagation and USNC/URSI National Radio Science Meeting, San Diego, United States, 5-12 July 2008. Piscataway, United States: IEEE. doi: 10.1109/APS.2008.4619670

A simple model for electromagnetic scattering due to breast tumour

2008

Conference Publication

Reproducibility of Automatic Quantitative Analysis of the Articular Cartilages from MEDIC and weDESS Magnetic Resonance Images of the Knee at 1.5T

Fripp, J., Jurcak, V., Holt, R., Ourselin, S., Engstrom, C. and Crozier, S. (2008). Reproducibility of Automatic Quantitative Analysis of the Articular Cartilages from MEDIC and weDESS Magnetic Resonance Images of the Knee at 1.5T. The International Society for Magnetic Resonance in Medicine's 16th Scientific Meeting and Exhibition, Toronto, Ontario, Canada, 3-9 May 2008. USA: International Society for Magnetic Resonance in Medicine.

Reproducibility of Automatic Quantitative Analysis of the Articular Cartilages from MEDIC and weDESS Magnetic Resonance Images of the Knee at 1.5T

2008

Conference Publication

Boundary Element Based Method for the Design of Biplanar Transverse Gradient Coils

Shou, Guofa, Ling, Xia, Liu,Feng, Sanchez Lopez, Hector, Li, Yu and Crozier, Stuart (2008). Boundary Element Based Method for the Design of Biplanar Transverse Gradient Coils. CSMRM & OCSMRM Joint Meeting 2008 and ESMRMB Workshop, Shenzhen, China, 13-15 SDec 2008.

Boundary Element Based Method for the Design of Biplanar Transverse Gradient Coils

2008

Conference Publication

A BiCG Solution Based Quasi-Static Finite-Difference Scheme for Induced Field Evaluation in MRI

Wang, H, Liu, F., Trakic, A. and Crozier, S. (2008). A BiCG Solution Based Quasi-Static Finite-Difference Scheme for Induced Field Evaluation in MRI. International Society for Magnetic Resonance in Medicine, Toronto, Ontario, Canada, 3-9 May 2008. USA: International Society for Magnetic Resonance in Medicine.

A BiCG Solution Based Quasi-Static Finite-Difference Scheme for Induced Field Evaluation in MRI

2008

Conference Publication

The design of planar transverse gradient coils using a deformation algorithm

Zhu, Minhua, Liu, Feng, Xia, Ling, Mehnert, Andrew, Sanchez Lopez, Hector, Wei, Qing, Crozier, Stuart, Zhu, Jianfeng, Jin, Zhaoyang, Zhang, Chenghui, Cui, Naxin and Xu, Wenlong (2008). The design of planar transverse gradient coils using a deformation algorithm. Progress In Electromagnetics Research Symposium (PIERS) 2008, Hangzhou, China, 24-28 March 2008.

The design of planar transverse gradient coils using a deformation algorithm

2008

Conference Publication

Numerical field evaluation of healthcare workers when bending towards high-field MRI magnets

Wang, H., Trakic, A., Liu, F. and Crozier, S. (2008). Numerical field evaluation of healthcare workers when bending towards high-field MRI magnets. ISMRM 16th Annual Scientific Meeting and Exhibition, Toronto, Ontario, Canada, 3-9 May, 2008. Baltimore, Md. U.S.A.: Wiley. doi: 10.1002/mrm.21441

Numerical field evaluation of healthcare workers when bending towards high-field MRI magnets

2007

Journal Article

On the accurate modeling of a complex antenna for breast tumor detection using a hybrid MOM/FDTD approach

Padhi, Shantanu, Liu, Feng, Li, Bing Keong, Shuley, Nicholas and Crozier, Stuart (2007). On the accurate modeling of a complex antenna for breast tumor detection using a hybrid MOM/FDTD approach. Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference, 6637-6640.

On the accurate modeling of a complex antenna for breast tumor detection using a hybrid MOM/FDTD approach

2007

Journal Article

An analytical approach to the design of quiet cylindrical asymmetric gradient coils in MRI

Forbes, Lawrence K, Brideson, Michael A, Crozier, Stuart and While, Peter T (2007). An analytical approach to the design of quiet cylindrical asymmetric gradient coils in MRI. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 31B (4), 218-236. doi: 10.1002/cmr.b.20095

An analytical approach to the design of quiet cylindrical asymmetric gradient coils in MRI

2007

Journal Article

Segmentation of the bones in MRIs of the knee using phase, magnitude, and shape information

Fripp, Jurgen, Bourgeat, Pierrick, Crozier, Stuart and Ourselin, Sebastien (2007). Segmentation of the bones in MRIs of the knee using phase, magnitude, and shape information. Academic Radiology, 14 (10), 1201-1208. doi: 10.1016/j.acra.2007.06.021

Segmentation of the bones in MRIs of the knee using phase, magnitude, and shape information

2007

Journal Article

The role of quadratus lumborum asymmetry in the occurrence of lesions in the lumbar vertebrae of cricket fast bowlers

de Visser, Hans, Adam, Clayton J., Crozier, Stuart and Pearcy, Mark J. (2007). The role of quadratus lumborum asymmetry in the occurrence of lesions in the lumbar vertebrae of cricket fast bowlers. Medical Engineering & Physics, 29 (8), 877-885. doi: 10.1016/j.medengphy.2006.09.010

The role of quadratus lumborum asymmetry in the occurrence of lesions in the lumbar vertebrae of cricket fast bowlers

2007

Conference Publication

Three-dimensional gradient coil structures for magnetic resonance imaging designed using-fuzzy membership functions

Sanchez, H., Liu, F., Trakic, A., Weber, E. and Crozier, S. (2007). Three-dimensional gradient coil structures for magnetic resonance imaging designed using-fuzzy membership functions. New York: I.E.E.E.. doi: 10.1109/TMAG.2007.902065

Three-dimensional gradient coil structures for magnetic resonance imaging designed using-fuzzy membership functions

2007

Journal Article

An MRI-dedicated parallel FDTD scheme

Wang, Hua, Trakic, Adnan, Xia, Ling, Liu, Feng and Crozier, Stuart (2007). An MRI-dedicated parallel FDTD scheme. Concepts In Magnetic Resonance Part B-magnetic Resonance Engineering, 31B (3), 147-161. doi: 10.1002/cmr.b.20092

An MRI-dedicated parallel FDTD scheme

2007

Journal Article

Longitudinal gradient coil optimization in the presence of transient eddy currents

Trakic, Adnan, Liu, Feng, Sanchez Lopez, Hector, Wang, Hua and Crozier, Stuart (2007). Longitudinal gradient coil optimization in the presence of transient eddy currents. Magnetic Resonance in Medicine, 57 (6), 1119-1130. doi: 10.1002/mrm.21243

Longitudinal gradient coil optimization in the presence of transient eddy currents

2007

Journal Article

Automatic segmentation of the bone and extraction of the bone-cartilage interface from magnetic resonance images of the knee

Fripp, Jurgen, Crozier, Stuart, Warfield, Simon K. and Ourselin, Sébastien (2007). Automatic segmentation of the bone and extraction of the bone-cartilage interface from magnetic resonance images of the knee. Physics In Medicine And Biology, 52 (6) 005, 1617-1631. doi: 10.1088/0031-9155/52/6/005

Automatic segmentation of the bone and extraction of the bone-cartilage interface from magnetic resonance images of the knee

2007

Journal Article

Software developed for obtaining GPS-derived total electron content values

Horvath, I. and Crozier, S. (2007). Software developed for obtaining GPS-derived total electron content values. Radio Science, 42 (2) RS2002, 1-20. doi: 10.1029/2006RS003452

Software developed for obtaining GPS-derived total electron content values

2007

Journal Article

A simple relationship for high efficiency–gradient uniformity tradeoff in multilayer asymmetric gradient coils for magnetic resonance imaging

Sanchez Lopez, H., Liu, F., Trakic, A. and Crozier, S. (2007). A simple relationship for high efficiency–gradient uniformity tradeoff in multilayer asymmetric gradient coils for magnetic resonance imaging. IEEE Transactions on Magnetics, 43 (2, Part 1), 523-532. doi: 10.1109/TMAG.2006.887177

A simple relationship for high efficiency–gradient uniformity tradeoff in multilayer asymmetric gradient coils for magnetic resonance imaging