2013 Conference Publication Application of Rotating RF Coil Array in B1 Shimming with Strict Local SAR ConstraintsJin Jin, Liu, Feng, Trakic, Adnan, Weber, Ewald and Crozier, Stuart (2013). Application of Rotating RF Coil Array in B1 Shimming with Strict Local SAR Constraints. ISMRM (International Society for Magnetic Resonance in Medicine), Salt Lake City, USA, 20-26 April 2013. |
2013 Conference Publication Efficient hybrid imaging reconstruction of sensitivity encoding parallel imaging performed on rotating radiofrequency coil arrayLi, Mingyan, Jin Jin, Liu, Feng, Trakic, Adnan and Crozier, Stuart (2013). Efficient hybrid imaging reconstruction of sensitivity encoding parallel imaging performed on rotating radiofrequency coil array. International Society for Magnetic Resonance in Medicine, 21st Annual Meeting and Exhibition, Salt Lake City, UT, United States, 20-26 April 2013. New York, NY, United States: International Society of Magnetic Resonance in Medicine. |
2013 Conference Publication Highly accelerated parallel MRI using rotating radiofrequency coil array at 7TLi, Mingyan, Jin Jin, Liu, Feng, Weber, Ewald, Trakic, Adnan and Crozier, Stuart (2013). Highly accelerated parallel MRI using rotating radiofrequency coil array at 7T. International Society for Magnetic Resonance in Medicine, Salt Lake City, Utah USA, 20-26 April 2013. |
2012 Journal Article Improving SAR estimations in MRI using subject-specific modelsJin, Jin, Liu, Feng, Weber, Ewald and Crozier, Stuart (2012). Improving SAR estimations in MRI using subject-specific models. Physics in Medicine and Biology, 57 (24), 8153-8171. doi: 10.1088/0031-9155/57/24/8153 |
2012 Journal Article The effect of sigh on cardiorespiratory synchronization in healthy sleeping infantsNguyen, Chinh D., Dakin, Carolyn, Yuill, Margaret, Crozier, Stuart and Wilson, Stephen (2012). The effect of sigh on cardiorespiratory synchronization in healthy sleeping infants. Sleep, 35 (12), 1643-1650. doi: 10.5665/sleep.2236 |
2012 Journal Article Automated detection, 3D segmentation and analysis of high resolution spine MR images using statistical shape modelsNeubert, A., Fripp, J., Engstrom, C., Schwarz, R., Lauer, L., Salvado, O. and Crozier, S. (2012). Automated detection, 3D segmentation and analysis of high resolution spine MR images using statistical shape models. Physics in Medicine and Biology, 57 (24), 8357-8376. doi: 10.1088/0031-9155/57/24/8357 |
2012 Journal Article A finite difference method for the design of gradient coils in MRI-an initial frameworkZhu, Minhua, Xia, Ling, Liu, Feng, Zhu, Jianfeng, Kang, Liyi and Crozier, Stuart (2012). A finite difference method for the design of gradient coils in MRI-an initial framework. Ieee Transactions On Biomedical Engineering, 59 (9 Article No.6153352) 6153352, 2412-2421. doi: 10.1109/TBME.2012.2188290 |
2012 Journal Article Simulation and analysis of the interactions between split gradient coils and a split magnet cryostat in an MRI-PET systemLiu, Limei, Sanchez-Lopez, Hector, Poole, Michael, Liu, Feng and Crozier, Stuart (2012). Simulation and analysis of the interactions between split gradient coils and a split magnet cryostat in an MRI-PET system. Journal of Magnetic Resonance, 222, 8-15. doi: 10.1016/j.jmr.2012.05.022 |
2012 Journal Article Minimax current density gradient coils: analysis of coil performance and heatingPoole, Michael S., While, Peter T., Sanchez Lopez, Hector and Crozier, Stuart (2012). Minimax current density gradient coils: analysis of coil performance and heating. Magnetic Resonance in Medicine, 68 (2), 639-648. doi: 10.1002/mrm.23248 |
2012 Journal Article An orthogonal-based decoupling method for MRI phased array coil designLi, Bing Keong, Wang, Hua, Trakic, Adnan, Engstrom, Craig, Weber, Ewald and Crozier, Stuart (2012). An orthogonal-based decoupling method for MRI phased array coil design. NMR in Biomedicine, 25 (6), 835-842. doi: 10.1002/nbm.1799 |
2012 Journal Article Advanced three-dimensional tailored RF pulse design in volume selective parallel excitationShao, Tingting, Xia, Ling, Tao, Guisheng, Chi, Jieru, Liu, Feng and Crozier, Stuart (2012). Advanced three-dimensional tailored RF pulse design in volume selective parallel excitation. IEEE Transactions on Medical Imaging, 31 (5) 6094221, 997-1007. doi: 10.1109/TMI.2011.2178035 |
2012 Journal Article Electromechanical design and construction of a rotating radio-frequency coil system for applications in magnetic resonanceTrakic, Adnan, Weber, Ewald, Li, Bing Keong, Wang, Hua, Liu, Feng, Engstrom, Craig and Crozier, Stuart (2012). Electromechanical design and construction of a rotating radio-frequency coil system for applications in magnetic resonance. IEEE Transactions on Biomedical Engineering, 59 (4), 1068-1075. doi: 10.1109/TBME.2012.2182993 |
2012 Journal Article Automated quantification of the synchrogram by recurrence plot analysisNguyen, Chinh Duc, Wilson, Stephen J. and Crozier, Stuart (2012). Automated quantification of the synchrogram by recurrence plot analysis. IEEE Transaction on Biomedical Engineering, 59 (4), 946-955. doi: 10.1109/TBME.2011.2179937 |
2012 Journal Article Inverse field-based approach for simultaneous B-1 mapping at high fields: A phantom based studyJin, Jin, Liu, Feng, Zuo, Zhentao, Xue, Rong, Li, Mingyan, Li, Yu, Weber, Ewald and Crozier, Stuart (2012). Inverse field-based approach for simultaneous B-1 mapping at high fields: A phantom based study. Journal of Magnetic Resonance, 217, 27-35. doi: 10.1016/j.jmr.2012.02.004 |
2012 Journal Article Reorientation of fiber orientation distributions using apodized point spread functionsRaffelt, David, Tournier, J-Donald, Crozier, Stuart, Connelly, Alan and Salvado, Olivier (2012). Reorientation of fiber orientation distributions using apodized point spread functions. Magnetic Resonance in Medicine, 67 (3), 844-855. doi: 10.1002/mrm.23058 |
2012 Journal Article Apparent fibre density: A novel measure for the analysis of diffusion-weighted magnetic resonance imagesRaffelt, David, Tournier, J.-Donald, Rose, Stephen, Ridgway, Gerard R., Henderson, Robert, Crozier, Stuart, Salvado, Olivier and Connelly, Alan (2012). Apparent fibre density: A novel measure for the analysis of diffusion-weighted magnetic resonance images. NeuroImage, 59 (4), 3976-3994. doi: 10.1016/j.neuroimage.2011.10.045 |
2012 Journal Article Rotational magnetic induction tomographyTrakic, Adnan, Eskandarnia, Neda, Li, Bing Keong, Weber, Ewald, Wang, Hua and Crozier, Stuart (2012). Rotational magnetic induction tomography. Measurement Science and Technology, 23 (2) 025402, 025402.1-025402.12. doi: 10.1088/0957-0233/23/2/025402 |
2012 Conference Publication Removal of electron contamination in longitudinal field MRI-Linac Systems: A Monte Carlo StudyOborn, B. M., Metcalfe, P., Butson, M., Crozier, S. and Keall, P. (2012). Removal of electron contamination in longitudinal field MRI-Linac Systems: A Monte Carlo Study. 54th Annual Meeting and Exhibition of the American Association of Physicists in Medicine (AAPM), Charlotte, NC, United States, 29 July-2 August 2012. College Park, MD, United States: American Association of Physicists in Medicine. doi: 10.1118/1.4735074 |
2012 Conference Publication A passive copper shield for the split MRI systemLimei Liu, Sanchez Lopez, Hector, Michael Poole, Weber, Ewald, Liu, Feng and Crozier, Stuart (2012). A passive copper shield for the split MRI system. 20th Annual Meeting of the International Society for Magnetic Resonance in Medicine (ISMRM), Melbourne, Australia, 5-11 May 2012. Berkeley, United States: International Society for Magnetic Resonance in Medicine. |
2012 Conference Publication An optimal central gap size for the split gradient coil designLiu, Limei, Sanchez Lopez, Hector, Poole, Michael, Liu, Feng and Crozier, Stuart (2012). An optimal central gap size for the split gradient coil design. 20th Annual Meeting of the International Society for Magnetic Resonance in Medicine (ISMRM), Melbourne, Australia, 5-11 May 2012. |