Skip to menu Skip to content Skip to footer

2021

Journal Article

Specimen-specific fracture risk curves of lumbar vertebrae under dynamic axial compression

Robinson, Dale L., Tse, Kwong Ming, Franklyn, Melanie, Zhang, JiangYue, Fernandez, Justin W., Ackland, David C. and Lee, Peter Vee Sin (2021). Specimen-specific fracture risk curves of lumbar vertebrae under dynamic axial compression. Journal of the Mechanical Behavior of Biomedical Materials, 118 104457, 1-11. doi: 10.1016/j.jmbbm.2021.104457

Specimen-specific fracture risk curves of lumbar vertebrae under dynamic axial compression

2021

Journal Article

Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading

Woodford, Sarah C., Robinson, Dale L., Edelmann, Cornelia, Mehl, Albert, Roehrle, Oliver, Vee Sin Lee, Peter and Ackland, David C. (2021). Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading. Annals of Biomedical Engineering, 49 (6), 1561-1571. doi: 10.1007/s10439-020-02688-6

Low-Profile Electromagnetic Field Sensors in the Measurement and Modelling of Three-Dimensional Jaw Kinematics and Occlusal Loading

2020

Journal Article

Measurement of normal and pathological mandibular and temporomandibular joint kinematics: a systematic review

Woodford, Sarah C., Robinson, Dale L., Mehl, Albert, Lee, Peter V. S. and Ackland, David C. (2020). Measurement of normal and pathological mandibular and temporomandibular joint kinematics: a systematic review. Journal of Biomechanics, 111 109994, 1-14. doi: 10.1016/j.jbiomech.2020.109994

Measurement of normal and pathological mandibular and temporomandibular joint kinematics: a systematic review

2020

Journal Article

Occlusion of the lumbar spine canal during high-rate axial compression

Robinson, Dale L., Tse, Kwong Ming, Franklyn, Melanie, Ackland, David C., Richardson, Martin D. and Lee, Peter Vee Sin (2020). Occlusion of the lumbar spine canal during high-rate axial compression. The Spine Journal, 20 (10), 1692-1704. doi: 10.1016/j.spinee.2020.05.095

Occlusion of the lumbar spine canal during high-rate axial compression

2020

Journal Article

Loss of bone density and bone strength following premenopausal risk-reducing bilateral salpingo-oophorectomy: a prospective controlled study (WHAM Study)

Jiang, H., Robinson, D. L., Lee, P. V. S., Krejany, E. O., Yates, C. J., Hickey, M. and Wark, J. D. (2020). Loss of bone density and bone strength following premenopausal risk-reducing bilateral salpingo-oophorectomy: a prospective controlled study (WHAM Study). Osteoporosis International, 32 (1), 101-112. doi: 10.1007/s00198-020-05608-5

Loss of bone density and bone strength following premenopausal risk-reducing bilateral salpingo-oophorectomy: a prospective controlled study (WHAM Study)

2020

Journal Article

Effect of sitting posture on pelvic injury risk under vertical loading

Tse, Kwong Ming, Robinson, Dale Lee, Franklyn, Melanie, Zhang, Jiang Yue, Spratley, E. Meade, Salzar, Robert Scott, Fernandez, Justin, Ackland, David Charles and Lee, Peter Vee Sin (2020). Effect of sitting posture on pelvic injury risk under vertical loading. Journal of the Mechanical Behavior of Biomedical Materials, 108 103780, 1-14. doi: 10.1016/j.jmbbm.2020.103780

Effect of sitting posture on pelvic injury risk under vertical loading

2020

Journal Article

Bone Measures by Dual-Energy X-Ray Absorptiometry and Peripheral Quantitative Computed Tomography in Young Women With Type 1 Diabetes Mellitus

Jiang, Hongyuan, Robinson, Dale L., Nankervis, Alison, Garland, Suzanne M., Callegari, Emma T., Price, Sarah, Lee, Peter V. S. and Wark, John D. (2020). Bone Measures by Dual-Energy X-Ray Absorptiometry and Peripheral Quantitative Computed Tomography in Young Women With Type 1 Diabetes Mellitus. Journal of Clinical Densitometry, 24 (2), 259-267. doi: 10.1016/j.jocd.2020.05.009

Bone Measures by Dual-Energy X-Ray Absorptiometry and Peripheral Quantitative Computed Tomography in Young Women With Type 1 Diabetes Mellitus

2020

Journal Article

A novel rat model of heterotopic ossification after polytrauma with traumatic brain injury

Brady, Rhys D., Zhao, Michael Z., Wong, Ker R., Casilla-Espinosa, Pablo M., Yamakawa, Glenn R., Wortman, Ryan C., Sun, Mujun, Grills, Brian L., Mychasiuk, Richelle, O'Brien, Terence J., Agoston, Denes, Lee, Peter V. S., McDonald, Stuart J., Robinson, Dale L. and Shultz, Sandy R. (2020). A novel rat model of heterotopic ossification after polytrauma with traumatic brain injury. Bone, 133 115263, 1-5. doi: 10.1016/j.bone.2020.115263

A novel rat model of heterotopic ossification after polytrauma with traumatic brain injury

2020

Journal Article

Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study

Robinson, Dale L., Safai, Lauren, Harandi, Vahidreza Jafari, Graf, Mark, Lizama, L. Eduardo Cofre, Lee, Peter, Galea, Mary P., Khan, Fary, Tse, Kwong Ming and Ackland, David C. (2020). Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study. Clinical Biomechanics, 73, 201-212. doi: 10.1016/j.clinbiomech.2020.01.017

Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study

2019

Journal Article

Predicting experimentally-derived failure load at the distal radius using finite element modelling based on peripheral quantitative computed tomography cross-sections (pQCT-FE): A validation study

Jiang, Hongyuan, Robinson, Dale L., McDonald, Matthew, Lee, Peter V. S., Kontulainen, Saija A., Johnston, James D., Yates, Christopher J. and Wark, John D. (2019). Predicting experimentally-derived failure load at the distal radius using finite element modelling based on peripheral quantitative computed tomography cross-sections (pQCT-FE): A validation study. Bone, 129 115051, 1-7. doi: 10.1016/j.bone.2019.115051

Predicting experimentally-derived failure load at the distal radius using finite element modelling based on peripheral quantitative computed tomography cross-sections (pQCT-FE): A validation study

2019

Journal Article

Cortical and Trabecular Bone Fracture Characterisation in the Vertebral Body Using Acoustic Emission

Robinson, Dale L., Tse, Kwong Ming, Franklyn, Melanie, Zhang, Jiang Yue, Ackland, David and Lee, Peter Vee Sin (2019). Cortical and Trabecular Bone Fracture Characterisation in the Vertebral Body Using Acoustic Emission. Annals of Biomedical Engineering, 47 (12), 2384-2401. doi: 10.1007/s10439-019-02316-y

Cortical and Trabecular Bone Fracture Characterisation in the Vertebral Body Using Acoustic Emission

2019

Journal Article

Peripheral quantitative computed tomography (pQCT)-based finite element analysis provides enhanced diagnostic performance in identifying non-vertebral fracture patients compared with dual-energy X-ray absorptiometry

Jiang, H., Robinson, D. L., Yates, C. J., Lee, P. V. S. and Wark, J. D. (2019). Peripheral quantitative computed tomography (pQCT)-based finite element analysis provides enhanced diagnostic performance in identifying non-vertebral fracture patients compared with dual-energy X-ray absorptiometry. Osteoporosis International, 31 (1), 141-151. doi: 10.1007/s00198-019-05213-1

Peripheral quantitative computed tomography (pQCT)-based finite element analysis provides enhanced diagnostic performance in identifying non-vertebral fracture patients compared with dual-energy X-ray absorptiometry

2019

Journal Article

Bone Health in Rats With Temporal Lobe Epilepsy in the Absence of Anti-Epileptic Drugs

Brady, Rhys D., Wong, Ker Rui, Robinson, Dale L., Mychasiuk, Richelle, McDonald, Stuart J., D'Cunha, Ryan A., Yamakawa, Glenn R., Sun, Mujun, Wark, John D., Lee, Peter Vee Sin, O'Brien, Terence J., Casillas-Espinosa, Pablo M. and Shultz, Sandy R. (2019). Bone Health in Rats With Temporal Lobe Epilepsy in the Absence of Anti-Epileptic Drugs. Frontiers in Pharmacology, 10 (OCT) 1278, 1-9. doi: 10.3389/fphar.2019.01278

Bone Health in Rats With Temporal Lobe Epilepsy in the Absence of Anti-Epileptic Drugs

2019

Journal Article

Load response of the natural tooth and dental implant: a comparative biomechanics study

Robinson, Dale, Aguilar, Luis, Gatti, Andrea, Abduo, Jaafar, Lee, Peter Vee Sin and Ackland, David (2019). Load response of the natural tooth and dental implant: a comparative biomechanics study. Journal of Advanced Prosthodontics, 11 (3), 169-178. doi: 10.4047/jap.2019.11.3.169

Load response of the natural tooth and dental implant: a comparative biomechanics study

2019

Journal Article

The application of finite element modelling based on clinical pQCT for classification of fracture status

Robinson, Dale L., Jiang, Hongyuan, Song, Qichun, Yates, Christopher, Lee, Peter Vee Sin and Wark, John D. (2019). The application of finite element modelling based on clinical pQCT for classification of fracture status. Biomechanics and Modeling in Mechanobiology, 18 (1), 245-260. doi: 10.1007/s10237-018-1079-7

The application of finite element modelling based on clinical pQCT for classification of fracture status

2019

Journal Article

The influence of rotator cuff tears on muscle and joint-contact loading after reverse total shoulder arthroplasty

Ackland, David C., Robinson, Dale L., Wilkosz, Adam, Wu, Wen, Richardson, Martin, Lee, Peter and Tse, Kwong Ming (2019). The influence of rotator cuff tears on muscle and joint-contact loading after reverse total shoulder arthroplasty. Journal of Orthopaedic Research, 37 (1), 211-219. doi: 10.1002/jor.24152

The influence of rotator cuff tears on muscle and joint-contact loading after reverse total shoulder arthroplasty

2018

Journal Article

Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint

Ackland, David, Robinson, Dale, Lee, Peter Vee Sin and Dimitroulis, George (2018). Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint. Clinical Biomechanics, 56, 52-60. doi: 10.1016/j.clinbiomech.2018.05.006

Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint

2018

Journal Article

Lumbar model generator: a tool for the automated generation of a parametric scalable model of the lumbar spine

Lavecchia, C. E., Espino, D. M., Moerman, K. M., Tse, K. M., Robinson, D., Lee, P. V. S. and Shepherd, D. E. T. (2018). Lumbar model generator: a tool for the automated generation of a parametric scalable model of the lumbar spine. Journal of the Royal Society Interface, 15 (138) 20170829, 1-13. doi: 10.1098/rsif.2017.0829

Lumbar model generator: a tool for the automated generation of a parametric scalable model of the lumbar spine

2017

Journal Article

A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation

Ackland, David C., Robinson, Dale, Redhead, Michael, Lee, Peter Vee Sin, Moskaljuk, Adrian and Dimitroulis, George (2017). A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation. Journal of the Mechanical Behavior of Biomedical Materials, 69, 404-411. doi: 10.1016/j.jmbbm.2017.01.048

A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation

2016

Journal Article

Mechanical properties of normal and osteoarthritic human articular cartilage

Robinson, Dale L., Kersh, Mariana E., Walsh, Nicole C., Ackland, David C., de Steiger, Richard N. and Pandy, Marcus G. (2016). Mechanical properties of normal and osteoarthritic human articular cartilage. Journal of the Mechanical Behavior of Biomedical Materials, 61, 96-109. doi: 10.1016/j.jmbbm.2016.01.015

Mechanical properties of normal and osteoarthritic human articular cartilage