Skip to menu Skip to content Skip to footer

1999

Conference Publication

A new approach to interpret the results of return voltage measurements on aged power transformers

Yao, Z., Saha, T. K. and Darveniza, M. (1999). A new approach to interpret the results of return voltage measurements on aged power transformers. AUPEC/EECON'99, Darwin, 26-29 Sept, 1999. Darwin: Northern Territory Univ..

A new approach to interpret the results of return voltage measurements on aged power transformers

1999

Conference Publication

Field experience with return voltage measurements for assessing insulation condition in transformers and its comparison with accelerated aged insulation samples

Saha, T. K., Darveniza, M. and Yao, Z. T. (1999). Field experience with return voltage measurements for assessing insulation condition in transformers and its comparison with accelerated aged insulation samples. ISH'99, London, 23-27 August 1999. London, UK: IEE.

Field experience with return voltage measurements for assessing insulation condition in transformers and its comparison with accelerated aged insulation samples

1999

Conference Publication

The service condition of distribution metal oxide surge arresters

Darveniza, M., Saha, T. K. and Wright, S. (1999). The service condition of distribution metal oxide surge arresters. Distribution 2000, Brisbane, 9-12 November 1999. Vic.: Waldren Smith Convention Network.

The service condition of distribution metal oxide surge arresters

1998

Conference Publication

Surface flashovers on metal-oxide varistor blocks

Darveniza Mat and Saha Tapan K. (1998). Surface flashovers on metal-oxide varistor blocks. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics, Vasteras, Sweden, June 22, 1998-June 25, 1998. NEW YORK: IEEE. doi: 10.1109/ICSD.1998.709311

Surface flashovers on metal-oxide varistor blocks

1997

Conference Publication

Electrical over-stress protection of electrical and electronic equipment - a new subject at the University of Queensland

Darveniza M. and Saha T.K. (1997). Electrical over-stress protection of electrical and electronic equipment - a new subject at the University of Queensland. Proceedings of the 1997 27th Annual Conference on Frontiers in Education. Part 3 (of 3), Pittsburgh, PA, USA, November 5, 1997-November 8, 1997. NEW YORK: I E E E. doi: 10.1109/fie.1997.636033

Electrical over-stress protection of electrical and electronic equipment - a new subject at the University of Queensland

1997

Conference Publication

Characterization of thermally accelerated aged oil-paper transformer insulation by interfacial polarization spectra measurements

Saha T.K. and Darveniza M. (1997). Characterization of thermally accelerated aged oil-paper transformer insulation by interfacial polarization spectra measurements. Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2), Seoul, Korea, May 25, 1997-May 30, 1997. NEW YORK: I E E E. doi: 10.1109/icpadm.1997.617636

Characterization of thermally accelerated aged oil-paper transformer insulation by interfacial polarization spectra measurements

1994

Conference Publication

Chemical degradation of cellulosic insulation paper for power transformers

Darveniza M., Hill D.J.T., Le T.T., Saha T.K. and Williams B. (1994). Chemical degradation of cellulosic insulation paper for power transformers. Proceedings of the 1994 IEEE 4th International Conference on Properties and Applications of Dielectric Materials. Part 2 (of 2), Brisbane, Aust, July 3, 1994-July 8, 1994. NEW YORK: IEEE. doi: 10.1109/icpadm.1994.414127

Chemical degradation of cellulosic insulation paper for power transformers

1994

Conference Publication

Monitoring the interfacial polarization parameters of transformers insulation for the assessment of ageing condition of transformer

Saha, T. K., Darveniza, M., Hill, D. J.T. and Le, T. T. (1994). Monitoring the interfacial polarization parameters of transformers insulation for the assessment of ageing condition of transformer. Proceedings of the 3rd Australasian Instrumentation and Measurement Conference, , , April 26, 1994-April 29, 1994. Publ by IE Aust.

Monitoring the interfacial polarization parameters of transformers insulation for the assessment of ageing condition of transformer

1994

Conference Publication

Condition monitoring of the bulk insulation of distribution transformers by electrical and chemical techniques

Darveniza M., Saha T.K., Hill D.J.T. and Le T.T. (1994). Condition monitoring of the bulk insulation of distribution transformers by electrical and chemical techniques. Proceedings of the 1994 IEEE 4th International Conference on Properties and Applications of Dielectric Materials. Part 2 (of 2), Brisbane, Aust, July 3, 1994-July 8, 1994. NEW YORK: I E E E. doi: 10.1109/icpadm.1994.414118

Condition monitoring of the bulk insulation of distribution transformers by electrical and chemical techniques

1994

Conference Publication

Studies of the condition of thermally aged transformer board insulation by electrical and chemical techniques

Darveniza M., Saha T.K., Hill D.J.T. and Le T.T. (1994). Studies of the condition of thermally aged transformer board insulation by electrical and chemical techniques. Proceedings of the 1994 IEEE 4th International Conference on Properties and Applications of Dielectric Materials. Part 2 (of 2), Brisbane, Aust, July 3, 1994-July 8, 1994. NEW YORK: IEEE. doi: 10.1109/icpadm.1994.414119

Studies of the condition of thermally aged transformer board insulation by electrical and chemical techniques

1993

Conference Publication

Life time of cellulose insulation paper in a power transformer

Darveniza, M., Hill, D. J. T., Le, T. T., Saha, T. K. and Williams, B. (1993). Life time of cellulose insulation paper in a power transformer. American Chemical Society National Meeting, -, -.

Life time of cellulose insulation paper in a power transformer

1992

Conference Publication

Assessment of insulation in aged power transformers by interfacial polarization spectrum and its correlation with chemical properties

Darveniza M., Saha T.K., Hill D.J.T. and Le T.T. (1992). Assessment of insulation in aged power transformers by interfacial polarization spectrum and its correlation with chemical properties. Sixth International Conference on Dielectric Materials, Measurements and Applications, Manchester, Engl, September 7, 1992-September 10, 1992. Publ by IEE.

Assessment of insulation in aged power transformers by interfacial polarization spectrum and its correlation with chemical properties

1992

Conference Publication

GEL-PERMEATION CHROMATOGRAPHY OF THE THERMAL-DEGRADATION OF CELLULOSE INSULATION PAPER IN AN AGED POWER TRANSFORMER

HILL, DJT, LE, TT, DARVENIZA, M, SAHA, TK and WILLIAMS, B (1992). GEL-PERMEATION CHROMATOGRAPHY OF THE THERMAL-DEGRADATION OF CELLULOSE INSULATION PAPER IN AN AGED POWER TRANSFORMER. 19Th Australian Polymer Symp ( Aps 19 ), Perth Australia, Feb, 1992. PARKVILLE: INST METALS MATER AUSTRALASIA LTD.

GEL-PERMEATION CHROMATOGRAPHY OF THE THERMAL-DEGRADATION OF CELLULOSE INSULATION PAPER IN AN AGED POWER TRANSFORMER

1991

Conference Publication

Studies of the condition of insulation in aged power transformers, part 2: Fundamental electrical and chemical considerations

Darveniza, M., Hill, D., Le, Tri and Saha, T. K. (1991). Studies of the condition of insulation in aged power transformers, part 2: Fundamental electrical and chemical considerations. Proceedings of the 3rd International Conference on Properties and Applications of Dielectric Materials, , , July 8, 1991-July 12, 1991. Publ by IEEE. doi: 10.1109/icpadm.1991.172273

Studies of the condition of insulation in aged power transformers, part 2: Fundamental electrical and chemical considerations

1985

Conference Publication

REAL-TIME DECOUPLED EQUIVALENT MODELS FOR STATIC SECURITY ANALYSIS

Durga Prasad, G., Hanmandlu, M. and Saha, Tapan K. (1985). REAL-TIME DECOUPLED EQUIVALENT MODELS FOR STATIC SECURITY ANALYSIS. Technical Papers - IEEE/PES 1985 Summer Meeting., , , IEEE.

REAL-TIME DECOUPLED EQUIVALENT MODELS FOR STATIC SECURITY ANALYSIS