Skip to menu Skip to content Skip to footer

2000

Journal Article

A new approach to interpret the results of return voltage measurements on aged power transformers

Yao, Z., Saha, T. K. and Darveniza, M. (2000). A new approach to interpret the results of return voltage measurements on aged power transformers. Journal of Electrical and Electronics Engineering, 20 (1), 29-33.

A new approach to interpret the results of return voltage measurements on aged power transformers

1999

Journal Article

Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation

Saha, T. K., Darveniza, M., Yao, Z. T., Hill, D. and Yeung, G. (1999). Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation. IEEE Power Engineering Review, 19 (3)

Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation

1999

Conference Publication

Neural networks for forecasting electricity pool price in a deregulated electricity supply industry

Sansom, D. and Saha, T. K. (1999). Neural networks for forecasting electricity pool price in a deregulated electricity supply industry. AUPEC/EECON'99, Darwin, Australia, 26-29 September 1999. Darwin: Northern Territory Univ..

Neural networks for forecasting electricity pool price in a deregulated electricity supply industry

1999

Conference Publication

The service condition of distribution metal oxide surge arresters

Darveniza, M., Saha, T. K. and Wright, S. (1999). The service condition of distribution metal oxide surge arresters. Distribution 2000, Brisbane, 9-12 November 1999. Vic.: Waldren Smith Convention Network.

The service condition of distribution metal oxide surge arresters

1999

Conference Publication

Return voltage measurement on metal oxide surge arresters

Saha, T. K. and Dinh, T. C. (1999). Return voltage measurement on metal oxide surge arresters. ISH'99, London, 23-27 August 1999. London, UK: IEE.

Return voltage measurement on metal oxide surge arresters

1999

Conference Publication

Modern electrical and chemical diagnostic methods for assessing ageing of transformer insulation - with special reference to recovery voltage analyses

Darveniza, M., Saha, T. K. and Hill, D. T. (1999). Modern electrical and chemical diagnostic methods for assessing ageing of transformer insulation - with special reference to recovery voltage analyses. CIGRE SC15, Sydney, 4 October 199. Sydney: Univ. of NSW.

Modern electrical and chemical diagnostic methods for assessing ageing of transformer insulation - with special reference to recovery voltage analyses

1999

Conference Publication

Effects of moisture on the recovery voltage measurement for aged transformer

Yao, Z., Saha, T. K. and Darveniza, M. (1999). Effects of moisture on the recovery voltage measurement for aged transformer. IPEC'99, Singapore, 24-26 May 1999. Singapore: Nanyang Technological Univ..

Effects of moisture on the recovery voltage measurement for aged transformer

1999

Conference Publication

A new approach to interpret the results of return voltage measurements on aged power transformers

Yao, Z., Saha, T. K. and Darveniza, M. (1999). A new approach to interpret the results of return voltage measurements on aged power transformers. AUPEC/EECON'99, Darwin, 26-29 Sept, 1999. Darwin: Northern Territory Univ..

A new approach to interpret the results of return voltage measurements on aged power transformers

1999

Conference Publication

Studies of in-service and laboratory failures of metal-oxide distribution surge arresters

Darveniza, M., Saha, T. K. and Wright, S. (1999). Studies of in-service and laboratory failures of metal-oxide distribution surge arresters. V SIPDA99, San Paulo, Brazil, 17-21 May 1999. San Paulo, Brazil: University of San Paulo.

Studies of in-service and laboratory failures of metal-oxide distribution surge arresters

1999

Conference Publication

Field experience with return voltage measurements for assessing insulation condition in transformers and its comparison with accelerated aged insulation samples

Saha, T. K., Darveniza, M. and Yao, Z. T. (1999). Field experience with return voltage measurements for assessing insulation condition in transformers and its comparison with accelerated aged insulation samples. ISH'99, London, 23-27 August 1999. London, UK: IEE.

Field experience with return voltage measurements for assessing insulation condition in transformers and its comparison with accelerated aged insulation samples

1999

Journal Article

Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation

Saha, TK, Darveniza, M, Yao, ZT, Hill, DJT and Yeung, G (1999). Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation. IEEE Transations on Power Delivery, 14 (4), 1359-1367. doi: 10.1109/61.796229

Investigating the effects of oxidation and thermal degradation on electrical and chemical properties of power transformers insulation

1998

Journal Article

Investigations into effective methods for assessing the condition of insulation in aged power transformers

Darveniza, M, Saha, TK and Hill, DJT (1998). Investigations into effective methods for assessing the condition of insulation in aged power transformers. Ieee Transactions On Power Delivery, 13 (4), 1214-1223. doi: 10.1109/61.714487

Investigations into effective methods for assessing the condition of insulation in aged power transformers

1998

Conference Publication

Surface flashovers on metal-oxide varistor blocks

Darveniza Mat and Saha Tapan K. (1998). Surface flashovers on metal-oxide varistor blocks. Proceedings of the 1998 IEEE 6th International Conference on Conduction and Breakdown in Solid Dielectrics, Vasteras, Sweden, June 22, 1998-June 25, 1998. NEW YORK: IEEE. doi: 10.1109/ICSD.1998.709311

Surface flashovers on metal-oxide varistor blocks

1997

Journal Article

Electrical and chemical diagnostics of transformers insulation .B. Accelerated aged insulation samples

Saha, TK, Darveniza, M, Hill, DJT and Le, TT (1997). Electrical and chemical diagnostics of transformers insulation .B. Accelerated aged insulation samples. Ieee Transactions On Power Delivery, 12 (4), 1555-1561. doi: 10.1109/61.634175

Electrical and chemical diagnostics of transformers insulation .B. Accelerated aged insulation samples

1997

Conference Publication

Characterization of thermally accelerated aged oil-paper transformer insulation by interfacial polarization spectra measurements

Saha T.K. and Darveniza M. (1997). Characterization of thermally accelerated aged oil-paper transformer insulation by interfacial polarization spectra measurements. Proceedings of the 1997 5th IEEE International Conference on Properties and Applications of Dielectric Materials. Part 1 (of 2), Seoul, Korea, May 25, 1997-May 30, 1997. NEW YORK: I E E E. doi: 10.1109/icpadm.1997.617636

Characterization of thermally accelerated aged oil-paper transformer insulation by interfacial polarization spectra measurements

1997

Conference Publication

Electrical over-stress protection of electrical and electronic equipment - a new subject at the University of Queensland

Darveniza M. and Saha T.K. (1997). Electrical over-stress protection of electrical and electronic equipment - a new subject at the University of Queensland. Proceedings of the 1997 27th Annual Conference on Frontiers in Education. Part 3 (of 3), Pittsburgh, PA, USA, November 5, 1997-November 8, 1997. NEW YORK: I E E E. doi: 10.1109/fie.1997.636033

Electrical over-stress protection of electrical and electronic equipment - a new subject at the University of Queensland

1997

Journal Article

Electrical and chemical diagnostics of transformers insulation .A. Aged transformer samples

Saha, T. K., Darveniza, M., Hill, D. J. T. and Le, T. T. (1997). Electrical and chemical diagnostics of transformers insulation .A. Aged transformer samples. Ieee Transactions On Power Delivery, 12 (4), 1547-1554. doi: 10.1109/61.634174

Electrical and chemical diagnostics of transformers insulation .A. Aged transformer samples

1996

Journal Article

A study of the degradation of cellulosic insulation materials in a power transformer. Part III: Degradation products of cellulose insulation paper

Hill, D. J. T., Le, T. T., Darveniza, M. and Saha, T. (1996). A study of the degradation of cellulosic insulation materials in a power transformer. Part III: Degradation products of cellulose insulation paper. Polymer Degradation and Stability, 51 (2), 211-218. doi: 10.1016/0141-3910(95)00204-9

A study of the degradation of cellulosic insulation materials in a power transformer. Part III: Degradation products of cellulose insulation paper

1995

Journal Article

A study of degradation of cellulosic insulation materials in a power transformer. Part 2: tensile strength of cellulose insulation paper

Hill, D. J. T., Le, T. T., Darveniza, M. and Saha, T. (1995). A study of degradation of cellulosic insulation materials in a power transformer. Part 2: tensile strength of cellulose insulation paper. Polymer Degradation and Stability, 49 (3), 429-435. doi: 10.1016/0141-3910(95)00100-Z

A study of degradation of cellulosic insulation materials in a power transformer. Part 2: tensile strength of cellulose insulation paper

1995

Journal Article

A study of degradation of cellulosic insulation materials in a power transformer, part 1. Molecular weight study of cellulose insulation paper

Hill, D. J. T., Le, T. T., Darveniza, M. and Saha, T. (1995). A study of degradation of cellulosic insulation materials in a power transformer, part 1. Molecular weight study of cellulose insulation paper. Polymer Degradation and Stability, 48 (1), 79-87. doi: 10.1016/0141-3910(95)00023-F

A study of degradation of cellulosic insulation materials in a power transformer, part 1. Molecular weight study of cellulose insulation paper