|
2017 Journal Article A simulation study on the design of gradient coils in MRI for the imaging area above the patient bedHu, Yang , Wang, Qiuliang, Hu, Xinning, Zhu, Xuchen , Crozier, Stuart, Wang, Yaohui and Liu, Feng (2017). A simulation study on the design of gradient coils in MRI for the imaging area above the patient bed. Measurement Science and Technology, 28 (3) 035402, 035402. doi: 10.1088/1361-6501/aa56cd |
|
2017 Journal Article A framework combining window width-level adjustment and Gaussian filter-based multi-resolution for automatic whole heart segmentationCai, Ken, Yang, Rongqian, Chen, Huazhou, Li, Lihua, Zhou, Jing, Ou, Shanxing and Liu, Feng (2017). A framework combining window width-level adjustment and Gaussian filter-based multi-resolution for automatic whole heart segmentation. Neurocomputing, 220, 138-150. doi: 10.1016/j.neucom.2016.03.106 |
|
2017 Journal Article Improved k - t PCA algorithm using artificial sparsity in dynamic MRIWang, Yiran, Chen, Zhifeng, Wang, Jing, Yuan, Lixia, Xia, Ling and Liu, Feng (2017). Improved k - t PCA algorithm using artificial sparsity in dynamic MRI. Computational and Mathematical Methods in Medicine, 2017 4816024, 4816024-12. doi: 10.1155/2017/4816024 |
|
2016 Journal Article An improved asymmetric gradient coil design for high-resolution MRI head imagingTang, Fangfang , Liu, Feng, Freschi, Fabio, Li, Yu, Repetto, Maurizio, Giaccone, Luca, Wang, Yaohui and Crozier, Stuart (2016). An improved asymmetric gradient coil design for high-resolution MRI head imaging. Physics in Medicine and Biology, 61 (24), 8875-8889. doi: 10.1088/1361-6560/61/24/8875 |
|
2016 Journal Article The design of decoupled even-order zonal superconducting shim coils for a 9.4 T whole-body MRIZhu, Xuchen, Wang, Qiuliang, Li, Yi, Hu, Yang, Chen, Wenbo and Liu, Feng (2016). The design of decoupled even-order zonal superconducting shim coils for a 9.4 T whole-body MRI. IEEE Transactions on Applied Superconductivity, 26 (8) 7539277, 1-8. doi: 10.1109/TASC.2016.2598775 |
|
2016 Journal Article Pseudo-Polar Fourier Transform based Compressed Sensing MRIYang, Yang, Liu, Feng, Li, Mingyan, Jin, Jin, Weber, Ewald, Liu, Qinghuo and Crozier, Stuart (2016). Pseudo-Polar Fourier Transform based Compressed Sensing MRI. IEEE Transactions on Biomedical Engineering, 99 (4) 7488260, 816-825. doi: 10.1109/TBME.2016.2578930 |
|
2016 Journal Article Dynamic updating atlas for heart segmentation with a nonlinear field-based modelCai, Ken, Yang, Rongqian, Yue, Hongwei, Li, Lihua, Ou, Shanxing and Liu, Feng (2016). Dynamic updating atlas for heart segmentation with a nonlinear field-based model. International Journal of Medical Robotics and Computer Assisted Surgery, 13 (3) e1785, 1-10. doi: 10.1002/rcs.1785 |
|
2016 Journal Article A large-scale measurement of dielectric properties of normal and malignant colorectal tissues obtained from cancer surgeries at Larmor frequenciesLi, Zhou, Deng, Guanhua, Li, Zhe, Xin, Sherman Xuegang, Duan, Song, Lan, Maoying, Zhang, Sa, Gao, Yixin, He, Jun, Zhang, Songtao, Tang, Hongming, Wang, Weiwei, Han, Shuai, Yang, Qing X., Zhuang, Ling, Hu, Jiani and Liu, Feng (2016). A large-scale measurement of dielectric properties of normal and malignant colorectal tissues obtained from cancer surgeries at Larmor frequencies. Medical Physics, 43 (11), 5991-5997. doi: 10.1118/1.4964460 |
|
2016 Journal Article High field superconducting magnet technologies for magnetic resonance imagingWang, Q., Li, Y., Yang, W., Dong, Z., Zhu, X., Hu, G., Hu, Y., Ni, Z., Xu, J., Cheng, J., Wang, H., Dai, Y., Yan, L., Liu, F., Xia, L., Cheng, W., Mu, X., Zheng, J., Niu, C., Wang, L., Zhu, G., Sun, W., Zhao, B., Li, X., Liu, J. and Yan, C. (2016). High field superconducting magnet technologies for magnetic resonance imaging. IEEE Transactions on Applied Superconductivity, 26 (7) 7480860, 1-7. doi: 10.1109/TASC.2016.2574357 |
|
2016 Journal Article Numerical assessment of the reduction of specific absorption rate by adding high dielectric materials for fetus MRI at 3 TLuo, Minmin, Hu, Can, Zhuang, Yayun, Chen, Wufan, Liu, Feng and Xin, Sherman Xuegang (2016). Numerical assessment of the reduction of specific absorption rate by adding high dielectric materials for fetus MRI at 3 T. Biomedizinische Technik, 61 (4), 455-461. doi: 10.1515/bmt-2015-0171 |
|
2016 Journal Article Asymmetric gradient coil design for use in a short, open bore magnetic resonance imaging scannerWang, Yaohui, Liu, Feng, Li, Yu, Tang, Fangfang and Crozier, Stuart (2016). Asymmetric gradient coil design for use in a short, open bore magnetic resonance imaging scanner. Journal of Magnetic Resonance, 269, 203-212. doi: 10.1016/j.jmr.2016.06.015 |
|
2016 Journal Article Quantitative analysis of the reconstruction errors of the currently popular algorithm of magnetic resonance electrical property tomography at the interfaces of adjacent tissuesDuan, Song, Xu, Chao, Deng, Guanhua, Wang, Jiajia, Liu, Feng and Xin, Sherman Xuegang (2016). Quantitative analysis of the reconstruction errors of the currently popular algorithm of magnetic resonance electrical property tomography at the interfaces of adjacent tissues. NMR in Biomedicine, 29 (6), 744-750. doi: 10.1002/nbm.3522 |
|
2016 Journal Article Intra-coil interactions in split gradient coils in a hybrid MRI-LINAC systemTang, Fangfang, Freschi, Fabio, Sanchez Lopez, Hector, Repetto, Maurizio, Liu, Feng and Crozier, Stuart (2016). Intra-coil interactions in split gradient coils in a hybrid MRI-LINAC system. Journal of Magnetic Resonance, 265 (3) 7479461, 52-58. doi: 10.1016/j.jmr.2016.01.013 |
|
2016 Journal Article Online dynamic cardiac imaging based on the elastic-net modelHong, Mingjian, Zhang, Haibiao, Lin, Mengran, Liu, Feng and Ge, Yongxin (2016). Online dynamic cardiac imaging based on the elastic-net model. Inverse Problems in Science and Engineering, 25 (2), 1-14. doi: 10.1080/17415977.2016.1141207 |
|
2016 Journal Article Passive shimming of a superconducting magnet using the L1-norm regularized least square algorithmKong, Xia, Zhu, Minhua, Xia, Ling, Wang, Qiuliang, Li, Yi, Zhu, Xuchen, Liu, Feng and Crozier, Stuart (2016). Passive shimming of a superconducting magnet using the L1-norm regularized least square algorithm. Journal of Magnetic Resonance, 263, 122-125. doi: 10.1016/j.jmr.2015.11.019 |
|
2016 Journal Article Simulation of multi-probe radiofrequency ablation guided by optical surgery navigation system under different active modesXu, Leyi, Cai, Ken, Yang, Rongqian, Lin, Qinyong, Yue, Hongwei and Liu, Feng (2016). Simulation of multi-probe radiofrequency ablation guided by optical surgery navigation system under different active modes. Computer Assisted Surgery, 21 (1), 107-116. doi: 10.1080/24699322.2016.1210679 |
|
2016 Journal Article Ultra-high Q one-dimensional hybrid PhC-SPP waveguide microcavity with large structure toleranceLiu, Feng, Zhang, Lingxuan, Lu, Xiaoyuan, Wang, Weiqiang, Wang, Leiran, Wang, Guoxi, Zhang, Wenfu and Zhao, Wei (2016). Ultra-high Q one-dimensional hybrid PhC-SPP waveguide microcavity with large structure tolerance. Journal of Modern Optics, 63 (12), 1158-1165. doi: 10.1080/09500340.2015.1130272 |
|
2015 Journal Article Simulation study of noise reduction methods for a split MRI system using a finite element methodWang, Y., Liu, F. and Crozier, S. (2015). Simulation study of noise reduction methods for a split MRI system using a finite element method. Medical Physics, 42 (12), 7122-7131. doi: 10.1118/1.4935864 |
|
2015 Journal Article Aliasing Artefact Suppression in Compressed Sensing MRI for Random Phase-Encode UndersamplingYang, Yang, Liu, Feng, Jin Z. and Crozier S. (2015). Aliasing Artefact Suppression in Compressed Sensing MRI for Random Phase-Encode Undersampling. IEEE Transactions on Biomedical Engineering, 62 (9) 7078916, 2215-2223. doi: 10.1109/TBME.2015.2419372 |
|
2015 Journal Article Determination of sample entropy and fuzzy measure entropy parameters for distinguishing congestive heart failure from normal sinus rhythm subjectsZhao, Lina, Wei, Shoushui, Zhang, Chengqiu, Zhang, Yatao, Jiang, Xinge, Liu, Feng and Liu, Chengyu (2015). Determination of sample entropy and fuzzy measure entropy parameters for distinguishing congestive heart failure from normal sinus rhythm subjects. Entropy, 17 (9), 6270-6288. doi: 10.3390/e17096270 |