2006

Other Outputs

Phased array coil for MRI

Crozier, Stuart, Liu, Feng, Li, Bing, Keong and Weber, Ewald (2006). Phased array coil for MRI. WO/2009/124340.

Phased array coil for MRI

2006

Conference Publication

A magnetization mapping approach for passive shim design in MRI

Sanchez Lopez, H, Liu, F, Trakic, A. and Crozier, S (2006). A magnetization mapping approach for passive shim design in MRI. 28th Annual International Conference IEEE Engineering in Medicine and Biology Society, New York, USA, 30 August - 3 September, 2006. USA: IEEE. doi: 10.1109/IEMBS.2006.259480

A magnetization mapping approach for passive shim design in MRI

2006

Conference Publication

FDTD study of an UWB radar technique for breast tumor detection

Wang, Hua, Bialkowski, Marek E., Liu, Feng and Crozier, Stuart (2006). FDTD study of an UWB radar technique for breast tumor detection. 16th International Conference on Microwaves, Radar and Wireless Communications, MIKON 2006, Krakow, Poland, 22-24 May, 2006. Krakow, Poland: Warsaw University of Technology. doi: 10.1109/MIKON.2006.4345362

FDTD study of an UWB radar technique for breast tumor detection

2006

Journal Article

Simulation of Brugada syndrome using cellular and three-dimensional whole-heart modeling approaches

Xia, Ling, Zhang, Yu, Zhang, Henggui, Wei, Qing, Liu, Feng and Crozier, Stuart (2006). Simulation of Brugada syndrome using cellular and three-dimensional whole-heart modeling approaches. Physiological Measurement, 27 (11) 006, 1125-1142. doi: 10.1088/0967-3334/27/11/006

Simulation of Brugada syndrome using cellular and three-dimensional whole-heart modeling approaches

2006

Conference Publication

FDTD Analysis of transient eddy currents induced by gradient coil switching in MRI

Trakic, Adnan, Wang, Hua, Liu, Feng, Sanchez Lopez, Hector and Crozier, Stuart (2006). FDTD Analysis of transient eddy currents induced by gradient coil switching in MRI. ISMRM 14th Scientific Meeting & Exhibition, Washington, USA, 6-12 May, 2006. California, USA: International Society for Magentic Resonance in Medicine (ISMRM).

FDTD Analysis of transient eddy currents induced by gradient coil switching in MRI

2006

Journal Article

Electrodynamic heart model construction and ECG simulation

Xia, L., Huo, M., Wei, Q., Liu, F. and Crozier, S. (2006). Electrodynamic heart model construction and ECG simulation. Methods of Information In Medicine, 45 (5), 564-573. doi: 10.1055/s-0038-1634119

Electrodynamic heart model construction and ECG simulation

2006

Conference Publication

An MRI-based beating heart model

Wei, Q., Crozier, S., Appleton, B. C., Xia,, Liu, F., Wilson, S. J., Strugnell, W., Slaughter, R. and Riley, R. (2006). An MRI-based beating heart model. International Society for Magnetic Resonance in Medicine, 14th Scientific Meeting & Exhibition, Washington, DC United States, 6-12 May 2006. Berkeley, CA United States: International Society for Magnetic Resonance in Medicine.

An MRI-based beating heart model

2006

Conference Publication

Tailoring magnetic field gradient design to magnet cryostat geometry

Trakic, A., Liu, F., Sanchez Lopez, H., Wang, H. and Crozier, S. (2006). Tailoring magnetic field gradient design to magnet cryostat geometry. 28th Annual International Conference on the IEEE Engineering in Medicine and Biology Society, New York, U.S.A., 30 August - 3 September, 2006. New Jersey, U.S.A.: IEEE. doi: 10.1109/IEMBS.2006.259223

Tailoring magnetic field gradient design to magnet cryostat geometry

2006

Journal Article

High-field magnetic resonance imaging with reduced field/tissue RF artefacts - A modeling study using hybrid MoM/FEM and FDTD technique

Li, B. K., Liu, F. and Crozier, S. (2006). High-field magnetic resonance imaging with reduced field/tissue RF artefacts - A modeling study using hybrid MoM/FEM and FDTD technique. IEEE Transactions On Electromagnetic Compatibility, 48 (4), 628-633. doi: 10.1109/TEMC.2006.884539

High-field magnetic resonance imaging with reduced field/tissue RF artefacts - A modeling study using hybrid MoM/FEM and FDTD technique

2006

Conference Publication

Transcieve Grappa: a scheme for high field imaging with reduced field/tissue RF artefact's

Li, B. K. J., Liu, F. and Crozier, S. (2006). Transcieve Grappa: a scheme for high field imaging with reduced field/tissue RF artefact's. EMC-Zurich in Singapore 2006, 17th International Zurich Symposium on Electromagnetic Compatibility, Singapore, 27 February - 3 March, 2006. Singapore: EMC-Zurich.

Transcieve Grappa: a scheme for high field imaging with reduced field/tissue RF artefact's

2006

Conference Publication

A High Performance FDTD Scheme for MRI Applications

Wang, Hua, Trakic, Adnan, Liu, Feng, Bialkowski, Marek E. and Crozier, Stuart (2006). A High Performance FDTD Scheme for MRI Applications. ISMRM 14th Scientific Meeting & Exhibition, Washington, USA, 6-12 May, 2006. USA: International Society for Magnetic Resonance in Medicine.

A High Performance FDTD Scheme for MRI Applications

2006

Journal Article

Transient temperature rise in a mouse due to low-frequency regional hyperthermia

Trakic, Adnan, Liu, Feng and Crozier, Stuart (2006). Transient temperature rise in a mouse due to low-frequency regional hyperthermia. Physics In Medicine and Biology, 51 (7), 1673-1691. doi: 10.1088/0031-9155/51/7/003

Transient temperature rise in a mouse due to low-frequency regional hyperthermia

2006

Journal Article

Analysis of transient eddy currents in MRI using a cylindrical FDTD method

Trakic, Adnan, Wang, Hua, Liu, Feng, Sanchez Lopez, Hector and Crozier, Stuart (2006). Analysis of transient eddy currents in MRI using a cylindrical FDTD method. IEEE Transactions On Applied Superconductivity, 16 (3) 1687913, 1924-1936. doi: 10.1109/TASC.2006.874000

Analysis of transient eddy currents in MRI using a cylindrical FDTD method

2006

Conference Publication

Torque-Figure of Merit Trade-off in Multi-Layer Asymmetric Gradient Coils

Sanchez Lopez, Hector, Liu, Feng, Trakic, Adnan and Crozier, Stuart (2006). Torque-Figure of Merit Trade-off in Multi-Layer Asymmetric Gradient Coils. ISMRM 14th Scientific Meeting & Exhibition, Washington, USA, 6-12 May, 2006. California, USA: International Society for Magentic Resonance in Medicine (ISMRM).

Torque-Figure of Merit Trade-off in Multi-Layer Asymmetric Gradient Coils

2006

Conference Publication

A comparison of different choices for the regularization parameter in inverse electrocardiography models

Shou, G F, Feng, M, Xia,, Wei, Q., Liu, F and Crozier, S (2006). A comparison of different choices for the regularization parameter in inverse electrocardiography models. 28th Annual International Conference IEEE Engineering in Medicine and Biology Society, New York, U.S.A., 30 August - 3 September, 2006. USA: IEEE. doi: 10.1109/IEMBS.2006.259671

A comparison of different choices for the regularization parameter in inverse electrocardiography models

2006

Conference Publication

High frequency electromagnetic analysis using hybrid MOM/FEM method

Li, B. K. J., Xu, B., Liu, F., Hui, H. T. and Crozier, S. (2006). High frequency electromagnetic analysis using hybrid MOM/FEM method. ISMRM 14th Scientific Meeting & Exhibition, Washington, USA, 6-12 May, 2006. California, USA: International Society for Magentic Resonance in Medicine (ISMRM).

High frequency electromagnetic analysis using hybrid MOM/FEM method

2005

Conference Publication

Model implementation and case study for the lossy, multilayered spherical head phantom in MRI application

Xu, Bin, Li, Bing Keong, Crazier, Stuart, Wei, Qing and Liu, Feng (2005). Model implementation and case study for the lossy, multilayered spherical head phantom in MRI application. 2005 27th Annual International Conference of the Engineering in Medicine and Biology Society, IEEE-EMBS 2005, , , September 1, 2005-September 4, 2005.

Model implementation and case study for the lossy, multilayered spherical head phantom in MRI application

2005

Journal Article

An inverse methodology for high-frequency RF coil design for MRI with de-emphasized B-1 fields

Xu, Bin, Wei, Qing, Liu, Feng and Crozier, Stuart (2005). An inverse methodology for high-frequency RF coil design for MRI with de-emphasized B-1 fields. Ieee Transactions on Biomedical Engineering, 52 (9), 1582-1587. doi: 10.1109/TBME.2005.851514

An inverse methodology for high-frequency RF coil design for MRI with de-emphasized B-1 fields

2005

Journal Article

Analysis of cardiac ventricular wall motion based on a three-dimensional electromechanical biventricular model

Xia, Ling, Huo, Meimei M., Wei, Qing, Liu, Feng and Crozier, Stuart (2005). Analysis of cardiac ventricular wall motion based on a three-dimensional electromechanical biventricular model. Physics in Medicine and Biology, 50 (8), 1901-1917. doi: 10.1088/0031-9155/50/8/018

Analysis of cardiac ventricular wall motion based on a three-dimensional electromechanical biventricular model

2005

Journal Article

Numerical evaluation of the fields induced by body motion in or near high-field MRI scanners

Crozier, Stuart and Liu, Feng (2005). Numerical evaluation of the fields induced by body motion in or near high-field MRI scanners. Progress In Biophysics and Molecular Biology, 87 (2-3), 267-278. doi: 10.1016/j.pbiomolbio.2004.08.002

Numerical evaluation of the fields induced by body motion in or near high-field MRI scanners