Skip to menu Skip to content Skip to footer
Mr Ewald Weber
Mr

Ewald Weber

Email: 
Phone: 
+61 7 334 69586

Overview

Availability

Mr Ewald Weber is:
Available for supervision

Fields of research

Qualifications

  • Postgraduate Diploma, University Politechnica of Timisoara

Works

Search Professor Ewald Weber’s works on UQ eSpace

95 works between 2005 and 2024

21 - 40 of 95 works

2015

Journal Article

In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla

Li, Mingyan, Jin, Jin, Zuo, Zhentao, Liu, Feng, Trakic, Adnan, Weber, Ewald, Zhuo, Yan, Xue, Rong and Crozier, Stuart (2015). In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla. Journal of Magnetic Resonance, 252, 29-40. doi: 10.1016/j.jmr.2014.12.004

In vivo sensitivity estimation and imaging acceleration with rotating RF coil arrays at 7 Tesla

2015

Conference Publication

Investigation of acoustic noise reduction method for MRI-LINAC hybrid system

Wang, Y. H., Liu, F., Weber, E. and Crozier, S. (2015). Investigation of acoustic noise reduction method for MRI-LINAC hybrid system. International Society for Magnetic Resonance in Medicine (ISMRM), Toronto, Canada, 30 May - 5 June 2015. International Society of Magnetic Resonance in Medicine.

Investigation of acoustic noise reduction method for MRI-LINAC hybrid system

2015

Conference Publication

A Fast and Practical Imaging Scheme for a Rotating RF Coil at 9.4T by Using Ultra-Short TE Sequence in Radial Trajectory, Investigation of acoustic noise reduction method for MRI-LINAC hybrid system

Li, M., Hugger, T., Weber, E., Jin, J., Liu, F., Ullman, P., Stark, S., Tesiram, Y., Yang, Y., Junge, S. and Crozier, S. (2015). A Fast and Practical Imaging Scheme for a Rotating RF Coil at 9.4T by Using Ultra-Short TE Sequence in Radial Trajectory, Investigation of acoustic noise reduction method for MRI-LINAC hybrid system. International Society for Magnetic Resonance in Medicine (ISMRM), Toronto, Canada, 30 May - 5 June 2015. International Society for Magnetic Resonance in Medicine.

A Fast and Practical Imaging Scheme for a Rotating RF Coil at 9.4T by Using Ultra-Short TE Sequence in Radial Trajectory, Investigation of acoustic noise reduction method for MRI-LINAC hybrid system

2015

Conference Publication

Design of a whole-body radio frequency coil for image-guided radiotherapy treatment in a MRI-LINAC system

Destruel, A., Weber, E., Hughes, I., Li, Y., Liu, F. and Crozier, S. (2015). Design of a whole-body radio frequency coil for image-guided radiotherapy treatment in a MRI-LINAC system. International Society for Magnetic Resonance in Medicine (ISMRM), Toronto, Canada, 30 May - 5 June 2015. International Society for Magentic Resonance in Medicine (ISMRM).

Design of a whole-body radio frequency coil for image-guided radiotherapy treatment in a MRI-LINAC system

2015

Conference Publication

Improving B1+ uniformity using segmented dielectric pads

Destruel, A., Jin, J., Liu, F., Li, M., Weber, E. and Crozier, S. (2015). Improving B1+ uniformity using segmented dielectric pads. International Society for Magnetic Resonance in Medicine (ISMRM), Toronto, Canada, 30 May - 5 June 2015. International Society for Magnetic Resonance in Medicine.

Improving B1+ uniformity using segmented dielectric pads

2014

Journal Article

Model for B-1 imaging in MRI using the rotating RF field

Trakic, Adnan, Jin, Jin, Weber, Ewald and Crozier, Stuart (2014). Model for B-1 imaging in MRI using the rotating RF field. Computational and Mathematical Methods in Medicine, 2014 (461647) 461647, 1-12. doi: 10.1155/2014/461647

Model for B-1 imaging in MRI using the rotating RF field

2014

Journal Article

Highly Accelerated Acquisition and Homogeneous Image Reconstruction with Rotating RF Coil Array at 7 T—A Phantom Based Study

Li, Mingyan, Zuo, Zhentao, Jin, Jin, Xue, Rong, Trakic, Adnan, Weber, Ewald, Liu, Feng and Crozier, Stuart (2014). Highly Accelerated Acquisition and Homogeneous Image Reconstruction with Rotating RF Coil Array at 7 T—A Phantom Based Study. Journal of Magnetic Resonance, 240, 102-112. doi: 10.1016/j.jmr.2013.11.002

Highly Accelerated Acquisition and Homogeneous Image Reconstruction with Rotating RF Coil Array at 7 T—A Phantom Based Study

2014

Conference Publication

Rotating RF Coil (RRFC) for Flip Angle and Specific Absorption Rate Management Applications at 7T MRI

Trakic, A., Jin, J., Li, M., Weber, E., Sanchez, H., Fuentes, M., Liu, F. and Crozier, S. (2014). Rotating RF Coil (RRFC) for Flip Angle and Specific Absorption Rate Management Applications at 7T MRI. International Society for Magnetic Resonance in Medicine (ISMRM), Milan, Italy, 10-16 May 2014. International Society for Magnetic Resonance in Medicine.

Rotating RF Coil (RRFC) for Flip Angle and Specific Absorption Rate Management Applications at 7T MRI

2014

Conference Publication

Evaluation of Electric Fields Induced in the Patient During Body Rotations in the Static Magnetic Field of a MRI-LINAC System

Trakic, A., Liu, L., Sanchez, H., Zilberti, L., Liu, F., Weber, E. and Crozier, S. (2014). Evaluation of Electric Fields Induced in the Patient During Body Rotations in the Static Magnetic Field of a MRI-LINAC System. International Society for Magnetic Resonance in Medicine (ISMRM), Milan, Italy, 10-16 May 2014. International Society for Magnetic Resonance in Medicine.

Evaluation of Electric Fields Induced in the Patient During Body Rotations in the Static Magnetic Field of a MRI-LINAC System

2014

Conference Publication

Inverse RF Array Head Coil Design for MRI-LINAC System

Wang. Y., Li, Y., Liu, F., Weber, E., Sanchez, H. and Crozier, S. (2014). Inverse RF Array Head Coil Design for MRI-LINAC System. International Society for Magnetic Resonance in Medicine (ISMRM), Milan, Italy, 10-16 May 2014. International Society for Magnetic Resonance in Medicine.

Inverse RF Array Head Coil Design for MRI-LINAC System

2013

Other Outputs

Method of estimating specific absorption rate

Crozier, Stuart, Weber, Ewald, Jin Jin and Liu, Feng (2013). Method of estimating specific absorption rate. WO2013181703 A1.

Method of estimating specific absorption rate

2013

Journal Article

A comparative numerical study of rotating and stationary RF coils in terms of flip angle and specific absorption rate for 7 T MRI

Trakic, A., Jin, J., Li, M., McClymont, D., Weber, E., Liu, F. and Crozier, S. (2013). A comparative numerical study of rotating and stationary RF coils in terms of flip angle and specific absorption rate for 7 T MRI. Journal of Magnetic Resonance, 236, 70-82. doi: 10.1016/j.jmr.2013.08.016

A comparative numerical study of rotating and stationary RF coils in terms of flip angle and specific absorption rate for 7 T MRI

2013

Journal Article

A MRI rotary phased array head coil

Li, Bing Keong, Weber, Ewald and Crozier, Stuart (2013). A MRI rotary phased array head coil. IEEE Transactions on Biomedical Circuits and Systems, 7 (4) 2230173, 548-556. doi: 10.1109/TBCAS.2012.2230173

A MRI rotary phased array head coil

2013

Conference Publication

On patient-specific models for accurate SAR estimations at 7 T

Jin Jin, Liu, Feng, Weber, Ewald and Crozier, Stuart (2013). On patient-specific models for accurate SAR estimations at 7 T. 21st Annual Meeting and Exhibition of the International Society for Magnetic Resonance in Medicine (ISMRM 2013), Salt Lake City, UT, United States, 20-26 April 2013.

On patient-specific models for accurate SAR estimations at 7 T

2013

Conference Publication

Highly accelerated parallel MRI using rotating radiofrequency coil array at 7T

Li, Mingyan, Jin Jin, Liu, Feng, Weber, Ewald, Trakic, Adnan and Crozier, Stuart (2013). Highly accelerated parallel MRI using rotating radiofrequency coil array at 7T. International Society for Magnetic Resonance in Medicine, Salt Lake City, Utah USA, 20-26 April 2013.

Highly accelerated parallel MRI using rotating radiofrequency coil array at 7T

2013

Conference Publication

Application of Rotating RF Coil Array in B1 Shimming with Strict Local SAR Constraints

Jin Jin, Liu, Feng, Trakic, Adnan, Weber, Ewald and Crozier, Stuart (2013). Application of Rotating RF Coil Array in B1 Shimming with Strict Local SAR Constraints. ISMRM (International Society for Magnetic Resonance in Medicine), Salt Lake City, USA, 20-26 April 2013.

Application of Rotating RF Coil Array in B1 Shimming with Strict Local SAR Constraints

2013

Conference Publication

B1 gradient encoding with the rotating RF coil

Trakic, Adnan, Weber, Ewald, Jin, Jin, Li, Mingyan, Liu, Feng and Crozier, Stuart (2013). B1 gradient encoding with the rotating RF coil. International Society for Magnetic Resonance in Medicine (ISMRM): 21st Scientific Meeting and Exhibition, Salt Lake City, UT, United States, 20-16 April 2013. New York, NY, United States: International Society of Magnetic Resonance in Medicine.

B1 gradient encoding with the rotating RF coil

2012

Journal Article

Improving SAR estimations in MRI using subject-specific models

Jin, Jin, Liu, Feng, Weber, Ewald and Crozier, Stuart (2012). Improving SAR estimations in MRI using subject-specific models. Physics in Medicine and Biology, 57 (24), 8153-8171. doi: 10.1088/0031-9155/57/24/8153

Improving SAR estimations in MRI using subject-specific models

2012

Journal Article

An orthogonal-based decoupling method for MRI phased array coil design

Li, Bing Keong, Wang, Hua, Trakic, Adnan, Engstrom, Craig, Weber, Ewald and Crozier, Stuart (2012). An orthogonal-based decoupling method for MRI phased array coil design. NMR in Biomedicine, 25 (6), 835-842. doi: 10.1002/nbm.1799

An orthogonal-based decoupling method for MRI phased array coil design

2012

Journal Article

Electromechanical design and construction of a rotating radio-frequency coil system for applications in magnetic resonance

Trakic, Adnan, Weber, Ewald, Li, Bing Keong, Wang, Hua, Liu, Feng, Engstrom, Craig and Crozier, Stuart (2012). Electromechanical design and construction of a rotating radio-frequency coil system for applications in magnetic resonance. IEEE Transactions on Biomedical Engineering, 59 (4), 1068-1075. doi: 10.1109/TBME.2012.2182993

Electromechanical design and construction of a rotating radio-frequency coil system for applications in magnetic resonance

Funding

Current funding

  • 2022 - 2025
    Evaluation of 7T 8-channel MRI coil for imaging of the human spine
    Aix-Marseille University
    Open grant

Past funding

  • 2014 - 2016
    Advanced Magnetic Resonance Imaging at 7 Tesla: Resolving the fundamental radiofrequency field-tissue interaction problem at ultra-high field
    ARC Discovery Projects
    Open grant
  • 2013 - 2016
    Real-time cardiac magnetic resonance imaging: a compressed-sensing framework incorporating sensor design and multidimensional signal reconstruction
    ARC Discovery Projects
    Open grant
  • 2010 - 2012
    Solutions for reducing magnetic resonance image degradations and tissue heating at high frequencies
    ARC Discovery Projects
    Open grant
  • 2008 - 2011
    Transceive Phased Arrays for Parallel Imaging in High Field Magnetic Resonance Microscopy.
    ARC Linkage Projects
    Open grant

Supervision

Availability

Mr Ewald Weber is:
Available for supervision

Before you email them, read our advice on how to contact a supervisor.

Media

Enquiries

For media enquiries about Mr Ewald Weber's areas of expertise, story ideas and help finding experts, contact our Media team:

communications@uq.edu.au