2016 Journal Article Assessment of the suitability of using a forehead EEG electrode set and chin EMG electrodes for sleep staging in polysomnographyMyllymaa, Sami, Muraja-Murro, Anu, Westeren-Punnonen, Susanna, Hukkanen, Taina, Lappalainen, Reijo, Mervaala, Esa, Töyräs, Juha, Sipilä, Kirsi and Myllymaa, Katja (2016). Assessment of the suitability of using a forehead EEG electrode set and chin EMG electrodes for sleep staging in polysomnography. Journal of Sleep Research, 25 (6), 636-645. doi: 10.1111/jsr.12425 |
2016 Journal Article Quantitative evaluation of the mechanical risks caused by focal cartilage defects in the kneeVenäläinen, Mikko S., Mononen, Mika E., Salo, Jari, Räsänen, Lasse P., Jurvelin, Jukka S., Töyräs, Juha, Virén, Tuomas and Korhonen, Rami K. (2016). Quantitative evaluation of the mechanical risks caused by focal cartilage defects in the knee. Scientific Reports, 6 (1) 37538, 1-12. doi: 10.1038/srep37538 |
2016 Journal Article Near infrared spectroscopic mapping of functional properties of equine articular cartilageSarin, Jaakko K., Amissah, Michael, Brommer, Harold, Argüelles, David, Töyräs, Juha and Afara, Isaac O. (2016). Near infrared spectroscopic mapping of functional properties of equine articular cartilage. Annals of Biomedical Engineering, 44 (11), 3335-3345. doi: 10.1007/s10439-016-1659-6 |
2016 Journal Article The AASM 2012 recommended hypopnea criteria increase the incidence of obstructive sleep apnea but not the proportion of positional obstructive sleep apneaDuce, Brett, Kulkas, Antti, Langton, Christian, Töyräs, Juha and Hukins, Craig (2016). The AASM 2012 recommended hypopnea criteria increase the incidence of obstructive sleep apnea but not the proportion of positional obstructive sleep apnea. Sleep Medicine, 26, 23-29. doi: 10.1016/j.sleep.2016.07.013 |
2016 Journal Article Cationic contrast agent diffusion differs between cartilage and meniscusHonkanen, Juuso T. J., Turunen, Mikael J., Freedman, Jonathan D., Saarakkala, Simo, Grinstaff, Mark W., Ylärinne, Janne H., Jurvelin, Jukka S. and Töyräs, Juha (2016). Cationic contrast agent diffusion differs between cartilage and meniscus. Annals of Biomedical Engineering, 44 (10), 2913-2921. doi: 10.1007/s10439-016-1629-z |
2016 Journal Article Optimal graft stiffness and pre-strain restore normal joint motion and cartilage responses in ACL reconstructed kneeHalonen, K. S., Mononen, M. E., Töyräs, J., Kröger, H., Joukainen, A. and Korhonen, R. K. (2016). Optimal graft stiffness and pre-strain restore normal joint motion and cartilage responses in ACL reconstructed knee. Journal of Biomechanics, 49 (13), 2566-2576. doi: 10.1016/j.jbiomech.2016.05.002 |
2016 Journal Article Differences in acoustic impedance of fresh and embedded human trabecular bone samples - scanning acoustic microscopy and numerical evaluationOjanen, Xiaowei, Töyräs, Juha, Inkinen, Satu I., Malo, Markus K. H., Isaksson, Hanna and Jurvelin, Jukka S. (2016). Differences in acoustic impedance of fresh and embedded human trabecular bone samples - scanning acoustic microscopy and numerical evaluation. Journal of the Acoustical Society of America, 140 (3), 1931-1936. doi: 10.1121/1.4962347 |
2016 Journal Article Effect of collagen cross-linking on quantitative MRI parameters of articular cartilageRautiainen, J., Nieminen, M. T., Salo, E. N., Kokkonen, H. T., Mangia, S., Michaeli, S., Gröhn, O., Jurvelin, J. S., Töyräs, J. and Nissi, M. J. (2016). Effect of collagen cross-linking on quantitative MRI parameters of articular cartilage. Osteoarthritis and Cartilage, 24 (9), 1656-1664. doi: 10.1016/j.joca.2016.04.017 |
2016 Journal Article Phased-array ultrasound technology enhances accuracy of dual frequency ultrasound measurements – towards improved ultrasound bone diagnosticsLinder, Hans, Malo, Markus K. H., Liukkonen, Jukka, Jurvelin, Jukka S. and Töyräs, Juha (2016). Phased-array ultrasound technology enhances accuracy of dual frequency ultrasound measurements – towards improved ultrasound bone diagnostics. Journal of Medical Engineering and Technology, 40 (6), 293-297. doi: 10.1080/03091902.2016.1185472 |
2016 Journal Article Optical coherence tomography enables accurate measurement of equine cartilage thickness for determination of speed of soundPuhakka, Pia H, te Moller, Nikae C R, Tanska, Petri, Saarakkala, Simo, Tiitu, Virpi, Korhonen, Rami K, Brommer, Harold, Virén, Tuomas, Jurvelin, Jukka S and Töyräs, Juha (2016). Optical coherence tomography enables accurate measurement of equine cartilage thickness for determination of speed of sound. Acta Orthopaedica, 87 (4), 418-424. doi: 10.1080/17453674.2016.1180578 |
2016 Journal Article Transport of iodine is different in cartilage and meniscusHonkanen, J. T.J., Turunen, M. J., Tiitu, V., Jurvelin, J. S. and Töyräs, J. (2016). Transport of iodine is different in cartilage and meniscus. Annals of Biomedical Engineering, 44 (7), 2114-2122. doi: 10.1007/s10439-015-1513-2 |
2016 Journal Article Finite difference time domain model of ultrasound propagation in agarose scaffold containing collagen or chondrocytesInkinen, Satu I., Liukkonen, Jukka, Malo, Markus K. H., Virén, Tuomas, Jurvelin, Jukka S. and Töyräs, Juha (2016). Finite difference time domain model of ultrasound propagation in agarose scaffold containing collagen or chondrocytes. Journal of the Acoustical Society of America, 140 (1), 1-7. doi: 10.1121/1.4953021 |
2016 Journal Article Importance of patella, quadriceps forces, and depthwise cartilage structure on knee joint motion and cartilage response during gaitHalonen, K. S., Mononen, M. E., Jurvelin, J. S., Töyräs, J., Kłodowski, A., Kulmala, J. P. and Korhonen, R. K. (2016). Importance of patella, quadriceps forces, and depthwise cartilage structure on knee joint motion and cartilage response during gait. Journal of Biomechanical Engineering, 138 (7) 071002. doi: 10.1115/1.4033516 |
2016 Journal Article In vivo evaluation of the potential of high-frequency ultrasound for arthroscopic examination of the shoulder jointPuhakka, Jani, Afara, Isaac O., Paatela, Teemu, Sormaala, Markus J., Timonen, Matti A., Virén, Tuomas, Jurvelin, Jukka S., Töyräs, Juha and Kiviranta, Ilkka (2016). In vivo evaluation of the potential of high-frequency ultrasound for arthroscopic examination of the shoulder joint. Cartilage, 7 (3), 248-255. doi: 10.1177/1947603515617280 |
2016 Journal Article Species-independent modeling of high-frequency ultrasound backscatter in hyaline cartilageMännicke, Nils, Schöne, Martin, Liukkonen, Jukka, Fachet, Dominik, Inkinen, Satu, Malo, Markus K., Oelze, Michael L., Töyräs, Juha, Jurvelin, Jukka S. and Raum, Kay (2016). Species-independent modeling of high-frequency ultrasound backscatter in hyaline cartilage. Ultrasound in Medicine and Biology, 42 (6), 1375-1384. doi: 10.1016/j.ultrasmedbio.2016.01.018 |
2016 Journal Article Effect of bone inhomogeneity on tibiofemoral contact mechanics during physiological loadingVenäläinen, M. S., Mononen, M. E., Väänänen, S. P., Jurvelin, J. S., Töyräs, J., Virén, T. and Korhonen, R. K. (2016). Effect of bone inhomogeneity on tibiofemoral contact mechanics during physiological loading. Journal of Biomechanics, 49 (7), 1111-1120. doi: 10.1016/j.jbiomech.2016.02.033 |
2016 Journal Article Effect of porosity, tissue density, and mechanical properties on radial sound speed in human cortical boneEneh, C. T.M., Malo, M. K.H., Karjalainen, J. P., Liukkonen, J., Töyräs, J. and Jurvelin, J. S. (2016). Effect of porosity, tissue density, and mechanical properties on radial sound speed in human cortical bone. Medical Physics, 43 (5), 2030-2039. doi: 10.1118/1.4942808 |
2016 Journal Article Articular cartilage repair with recombinant human type II collagen/polylactide scaffold in a preliminary porcine studyMuhonen, Virpi, Salonius, Eve, Haaparanta, Anne-Marie, Järvinen, Elina, Paatela, Teemu, Meller, Anna, Hannula, Markus, Björkman, Mimmi, Pyhältö, Tuomo, Ellä, Ville, Vasara, Anna, Töyräs, Juha, Kellomäki, Minna and Kiviranta, Ilkka (2016). Articular cartilage repair with recombinant human type II collagen/polylactide scaffold in a preliminary porcine study. Journal of Orthopaedic Research, 34 (5), 745-753. doi: 10.1002/jor.23099 |
2016 Journal Article Correlation of subchondral bone density and structure from plain radiographs with micro computed tomography ex vivoHirvasniemi, Jukka, Thevenot, Jérôme, Kokkonen, Harri T., Finnilä, Mikko A., Venäläinen, Mikko S., Jämsä, Timo, Korhonen, Rami K., Töyräs, Juha and Saarakkala, Simo (2016). Correlation of subchondral bone density and structure from plain radiographs with micro computed tomography ex vivo. Annals of Biomedical Engineering, 44 (5), 1698-1709. doi: 10.1007/s10439-015-1452-y |
2016 Journal Article RemLogic plug-in enables clinical application of apnea-hypopnea index adjusted for severity of individual obstruction eventsLeppänen, Timo, Särkkä, Mikko, Kulkas, Antti, Muraja-Murro, Anu, Kupari, Salla, Anttonen, Meri, Tiihonen, Pekka, Mervaala, Esa and Töyräs, Juha (2016). RemLogic plug-in enables clinical application of apnea-hypopnea index adjusted for severity of individual obstruction events. Journal of Medical Engineering and Technology, 40 (3), 119-126. doi: 10.3109/03091902.2016.1148791 |