
Overview
Background
my research interests are in the design of diagnostic medical devices and new applications for those devices
Prof Crozier is the director of Biomedical Engineering at UQ. He holds a higher doctorate in engineering for his work in improving the technology of imaging equipment. Stuart was elelcted as a fellow of the institute of physics (UK) in 2004 and hold many national and international grants relating to medical imaging and medical devices.
Availability
- Emeritus Professor Stuart Crozier is:
- Available for supervision
- Media expert
Fields of research
Qualifications
- Bachelor (Honours) of Engineering, Queensland University of Technology
- Masters (Coursework) of Applied Science, Queensland University of Technology
- Doctor of Philosophy, The University of Queensland
Works
Search Professor Stuart Crozier’s works on UQ eSpace
2007
Conference Publication
Numerical study of currents in occupational workers induced by body-motion around high-ultrahigh field MRI magnets
Crozier, Stuart, Trakic, Adnan, Wang, Hua and Liu, Feng (2007). Numerical study of currents in occupational workers induced by body-motion around high-ultrahigh field MRI magnets. Joint Annual Meeting ISMRM-ESMRMB, Berlin, Germany, 19-25 May, 2007.
2007
Journal Article
A new Heart rate variability analysis method by means of quantifying the variation of nonlinear dynamic patterns
Ding, H, Crozier, S and Wilson, S (2007). A new Heart rate variability analysis method by means of quantifying the variation of nonlinear dynamic patterns. Ieee Transactions On Biomedical Engineering, 54 (9), 1590-1597. doi: 10.1109/TBME.2007.893495
2007
Journal Article
Numerical study of currents in workers induced by body-motion around high-ultrahigh field MRI magnets
Crozier, Stuart, Trakic, Adnan, Wang, Hua and Liu, Feng (2007). Numerical study of currents in workers induced by body-motion around high-ultrahigh field MRI magnets. Journal of Magnetic Resonance Imaging, 26 (5), 1261-1277. doi: 10.1002/jmri.21160
2007
Conference Publication
An improved quasi-static finite-difference scheme for induced field evaluation in MRI based on the biconjugate gradient method
Wang, H., Liu, F., Trakic, A., Xia, L. and Crozier, S. (2007). An improved quasi-static finite-difference scheme for induced field evaluation in MRI based on the biconjugate gradient method. 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2007), Lyon, France, 23-26 August 2007. Piscataway, NJ, U.S.A.: IEEE - Institute of Electrical Electronics Engineers Inc.. doi: 10.1109/IEMBS.2007.4352329
2007
Conference Publication
A fast parallel imaging rotary phased array head coil with improved sensitivity profile deep in the center of the brain
Weber, E., Li, B. K., Liu, F. and Crozier, S. (2007). A fast parallel imaging rotary phased array head coil with improved sensitivity profile deep in the center of the brain. 29th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2007), Lyon, France, 23-26 August 2007. Piscataway, NJ, United States: IEEE - Institute of Electrical Electronics Engineers . doi: 10.1109/IEMBS.2007.4352333
2007
Conference Publication
Modelling regulatory compliance of occupationally exposed MRI workers during gradient pulsing
Wang, Hua, Trakic, Adnan, Liu, Feng and Crozier, Stuart (2007). Modelling regulatory compliance of occupationally exposed MRI workers during gradient pulsing. Joint Annual Meeting ISMRM-ESMRMB, Berlin, Germany, 19-25 May, 2007.
2007
Conference Publication
Hardware-accelerated volume visualisation of parametrically mapped dynamic breast MRI data
Vidholm, E., Mehnert, A.J.H., Bengtsson, E., Wildermoth, M., McMahon, K., Wilson, S.J. and Crozier, S. (2007). Hardware-accelerated volume visualisation of parametrically mapped dynamic breast MRI data. MICCAI 2007: The 10th International Conference on Medical Image Computing and Computer Assisted Intervention, Brisbane, Australia, 29 October - 2 November, 2007. Australia: MICCAI.
2007
Conference Publication
Initial measurements with an ambulatory static and gradient magnetic field dosimeter for workers in MRI
Fuentes, M. A., Crozier, S. and Wilson, S. (2007). Initial measurements with an ambulatory static and gradient magnetic field dosimeter for workers in MRI. ISMRM-ESMRMB Joint Annual Meeting 2007, Berlin, Germany, 19-25 May 2007. Berkely, CA, United States: International Society for Magnetic Resonance in Medicine.
2007
Conference Publication
3D-gradient coil structures for breast imaging using fuzzy membership functions, Part II
Sanchez Lopez, H., Liu, F., Weber, E. and Crozier, S. (2007). 3D-gradient coil structures for breast imaging using fuzzy membership functions, Part II. International Society for Magnetic Resonance in Medicine - ISMRM, Berlin, Germany, 19-25 May, 2007. USA: International Society for Magnetic Resonance in Medicine - ISMRM.
2007
Conference Publication
Numerical study of currents in occupational workers induced by body-motion around high-ultrahigh field MRI magnets
Crozier, S., Trakic, A., Wang. H. and Liu, F. (2007). Numerical study of currents in occupational workers induced by body-motion around high-ultrahigh field MRI magnets. International Society for Magnetic Resonance in Medicine, 15th Scientific Meeting and Exhibition, Berlin, Germany, 19-25 May 2007.
2007
Conference Publication
Visual quality assessment of watermarked medical images
Dowling, Jason A., Planitz, Birgit M., Maeder, Anthony J., Du, Jiang Du, Pham, Binh, Boyd, Colin, Chen, Shaokang, Bradley, Andrew P. and Crozier, Stuart (2007). Visual quality assessment of watermarked medical images. Medical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment, San Diego, USA, 21-22 February 2007. Bellingham, Wash., U.S.A.: SPIE - International Society for Optical Engineering. doi: 10.1117/12.707571
2007
Journal Article
Synthesizing dental radiographs for human identification
Tohnak, S., Mehnert, A. J., Mahoney, M. and Crozier, S. (2007). Synthesizing dental radiographs for human identification. Journal of Dental Research, 86 (11), 1057-1062. doi: 10.1177/154405910708601107
2006
Journal Article
Effect Of Cardiac Motion On Body Surface Electrocardiographic Potentials: An MRI-Based Simulation Study
Wei, Qing, Liu, Feng, Appleton, Ben, Xia, Ling, Liu, Nianjun, Wilson, Stephen, Riley, Robyn, Strugnel, Wendy, Slaughter, Richard, Denman, Russel and Crozier, Stuart (2006). Effect Of Cardiac Motion On Body Surface Electrocardiographic Potentials: An MRI-Based Simulation Study. Physics in Medicine and Biology, 51 (14) 009, 3405-3418. doi: 10.1088/0031-9155/51/14/009
2006
Conference Publication
A subdivision-based parametric deformable model for surface extraction and statistical shape modeling of the knee cartilages
Fripp, Jurgen, Crozier, Stuart, Warfield, Simon K. and Ourselin, Sébastien (2006). A subdivision-based parametric deformable model for surface extraction and statistical shape modeling of the knee cartilages. Medical Imaging 2006: Visualization, Image-Guided Procedures, and Display, , , February 12, 2006-February 14, 2006. doi: 10.1117/12.652919
2006
Journal Article
FDTD investigations into UWB radar technique of breast tumor detection and location
Wang, Hua, Bialkowski, Marek E., Liu, Feng and Crozier, Stuart (2006). FDTD investigations into UWB radar technique of breast tumor detection and location. African Journal of Information and Communication Technology, 2 (2), 81-87. doi: 10.5130/ajict.v2i2.230
2006
Journal Article
Multiple-acquisition parallel imaging combined with a transceive array for the amelioration of high-field RF distortion: a modeling study
Li, Bing Keong, Xu, Bin, Liu, Feng and Crozier, Stuart (2006). Multiple-acquisition parallel imaging combined with a transceive array for the amelioration of high-field RF distortion: a modeling study. Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering, 29B (2), 95-105. doi: 10.1002/cmr.b.20060
2006
Journal Article
A planar microwave imaging system with step-frequency synthesized pulse using different calibration methods
Bialkowski, Marek E., Khor, Wee Chang and Crozier, Stuart (2006). A planar microwave imaging system with step-frequency synthesized pulse using different calibration methods. Microwave And Optical Technology Letters, 48 (3), 511-516. doi: 10.1002/mop.21395
2006
Other Outputs
Phased array coil for MRI
Crozier, Stuart, Liu, Feng, Li, Bing, Keong and Weber, Ewald (2006). Phased array coil for MRI. WO/2009/124340.
2006
Conference Publication
Detection of small changes in a hip prothesis using the E-pulse technique
Lui, H S, Shuley, N V Z and Crozier, S (2006). Detection of small changes in a hip prothesis using the E-pulse technique. IEEE Antennas and Propagation Society International Symposium 2006, Albuquerque, USA, 9-14 July, 2006. Albuquerque, USA: IEEE. doi: 10.1109/APS.2006.1711023
2006
Conference Publication
FDTD Analysis of transient eddy currents induced by gradient coil switching in MRI
Trakic, Adnan, Wang, Hua, Liu, Feng, Sanchez Lopez, Hector and Crozier, Stuart (2006). FDTD Analysis of transient eddy currents induced by gradient coil switching in MRI. ISMRM 14th Scientific Meeting & Exhibition, Washington, USA, 6-12 May, 2006. California, USA: International Society for Magentic Resonance in Medicine (ISMRM).
Funding
Past funding
Supervision
Availability
- Emeritus Professor Stuart Crozier is:
- Available for supervision
Before you email them, read our advice on how to contact a supervisor.
Supervision history
Current supervision
-
Doctor Philosophy
Novel deep learning approaches to understanding human diseases
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
Doctor Philosophy
Innovative RF Coil Designs and Metamaterial Applications for Ultra-High Field MRI
Associate Advisor
Other advisors: Dr Lei Guo, Professor Feng Liu
-
Doctor Philosophy
Manifold Learning for Magnetic Resonance Imaging
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
Doctor Philosophy
Foundational models for visual recognition
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
Doctor Philosophy
Deep Learning Applied to Medical Image Analysis
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
Doctor Philosophy
Improving Feature Extraction and Feature Interpretability for Deep Learning in Medical Image Analysis
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
Doctor Philosophy
The design of metamaterial RF shield to reduce specific absorption rate and improve B1 efficiency for ultra-high field MRI
Associate Advisor
Other advisors: Dr Lei Guo, Professor Feng Liu
-
Doctor Philosophy
Manifold Learning for Magnetic Resonance Imaging
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
Doctor Philosophy
Deployable and Explainable Deep Learning Architectures: Navigating Clinical Challenges in Medical Image Segmentation
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
Doctor Philosophy
Innovative RF Coil Designs and Metamaterial Applications for Ultra-High Field MRI
Associate Advisor
Other advisors: Dr Lei Guo, Professor Feng Liu
-
Doctor Philosophy
Medical Shape Analysis of 3D MRI Segmentation with Deep Learning
Associate Advisor
Other advisors: Dr Shakes Chandra
Completed supervision
-
2019
Doctor Philosophy
Radiofrequency safety and shimming near metal hip prostheses at high and ultra-high field MRI
Principal Advisor
Other advisors: Professor Feng Liu, Professor Markus Barth
-
2017
Doctor Philosophy
Advanced modelling and optimization of gradient coils and their physical behaviour in traditional and paired MRI systems.
Principal Advisor
-
2017
Doctor Philosophy
Gradient Coil Design and Acoustic Noise Control in Magnetic Resonance Imaging Systems
Principal Advisor
Other advisors: Professor Feng Liu
-
2017
Doctor Philosophy
Automated Image Analysis of High-field and Dynamic Musculoskeletal MRI
Principal Advisor
Other advisors: Associate Professor Craig Engstrom
-
2016
Doctor Philosophy
Focusing Microwave Hyperthermia in Realistic Environment for Breast Cancer Treatment
Principal Advisor
Other advisors: Professor Amin Abbosh
-
2015
Doctor Philosophy
The Development of Rotating Radiofrequency Techniques for Ultra-High Field Magnetic Resonance Imaging
Principal Advisor
Other advisors: Professor Feng Liu
-
2015
Doctor Philosophy
Automated Segmentation and Quantitative Analysis of the Hip Joint from Magnetic Resonance Images
Principal Advisor
Other advisors: Associate Professor Craig Engstrom
-
2014
Doctor Philosophy
Clinically based computerized analysis of magnetic resonance imaging of the spine
Principal Advisor
-
-
2012
Doctor Philosophy
Computer-assisted Dental Comparison for Forensic Identification of Human Remains
Principal Advisor
-
2012
Doctor Philosophy
Voxel-Based Analysis of High Angular Resolution Diffusion-Weighted Magnetic Resonance Images
Principal Advisor
-
2011
Doctor Philosophy
Transceive Phased-array Systems for Parallel MRI
Principal Advisor
Other advisors: Professor Feng Liu
-
2011
Master Philosophy
Thoracic electrical impedance model: Investigation into the contribution of ventricular blood volume to the impedance cardiogram.
Principal Advisor
Other advisors: Professor Feng Liu
-
2010
Doctor Philosophy
Exploration of Information in Recurrence Plots to Discriminate Human Heart Rate Variability
Principal Advisor
-
2008
Doctor Philosophy
Automatic Segmentation of the Kneebone and Cartliages
Principal Advisor
-
2008
Doctor Philosophy
Numerical Simulation Tools Design for Field Evaluation in Biomedical Engineering
Principal Advisor
-
2007
Doctor Philosophy
NUMERICAL MODELLING OF ELECTROMAGNETIC FIELD - MATERIAL INTERACTIONS IN MAGNETIC RESONANCE IMAGING
Principal Advisor
Other advisors: Professor Feng Liu
-
2006
Doctor Philosophy
ELECTROMAGNETIC ANALYSIS AND DESIGN OF HIGH FREQUENCY COILS FOR MAGNETIC RERSONANCE
Principal Advisor
-
2006
Doctor Philosophy
MONITORING THE FLUID FLOW CHARACTERISTICS OF THE OVINE LUMBAR DISC USING MAGNETIC RESONANCE IMAGING AND FINITE ELEMENT ANAYLSIS
Principal Advisor
Other advisors: Professor Martin Veidt
-
2006
Doctor Philosophy
THE DESIGN AND ANALYSIS OF HIGH FREQUENCY PHASED ARRAY COILS FOR MRI
Principal Advisor
-
2015
Doctor Philosophy
Computer assisted detection and characterisation of breast cancer in MRI
Joint Principal Advisor
-
2024
Doctor Philosophy
Innovative RF Coil Designs and Metamaterial Applications for Ultra-High Field MRI
Associate Advisor
Other advisors: Dr Lei Guo, Professor Feng Liu
-
2024
Doctor Philosophy
Deployable and Interpretable Deep Learning Architectures: Navigating Clinical Challenges in Medical Image Segmentation
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
2024
Doctor Philosophy
Key Applications in Deep Learning Based Quantitative Susceptibility Mapping
Associate Advisor
Other advisors: Dr Hongfu Sun, Professor Feng Liu
-
2022
Doctor Philosophy
Improving deep learning-based fast MRI with pre-acquired image guidance
Associate Advisor
Other advisors: Dr Shakes Chandra, Professor Feng Liu
-
2022
Doctor Philosophy
Automated Assessment of Cartilage Composition and Cam Morphology using Magnetic Resonance Images of the Hip Joint
Associate Advisor
Other advisors: Associate Professor Craig Engstrom, Dr Shakes Chandra
-
2022
Doctor Philosophy
Deep Learning-based Quantitative Susceptibility Mapping: Methods Development and Applications
Associate Advisor
Other advisors: Dr Hongfu Sun, Professor Feng Liu
-
2021
Doctor Philosophy
Correction of Magnetic Resonance Image Distortion due to Gradient Nonlinearity in the Australian MRI-Linac System
Associate Advisor
Other advisors: Professor Feng Liu
-
2020
Doctor Philosophy
Magnetic Resonance Based Electrical Properties Tomography in High/Ultra-High Field MRI
Associate Advisor
Other advisors: Professor Feng Liu
-
2020
Doctor Philosophy
Incorporating advanced imaging into the treatment of brain tumours.
Associate Advisor
-
2008
Doctor Philosophy
High Performance Electromagnetic Computing for Biomedical Applications
Joint Principal Advisor
-
2020
Doctor Philosophy
Computer aided lesion detection, segmentation and characterization on mammography and breast MRI
Associate Advisor
Other advisors: Dr Shakes Chandra
-
2018
Doctor Philosophy
Frequency-Based Microwave Medical Imaging Techniques
Associate Advisor
Other advisors: Professor Amin Abbosh
-
2016
Doctor Philosophy
Gradient coil design and intra-coil eddy currents in MRI systems
Associate Advisor
Other advisors: Professor Feng Liu
-
2016
Doctor Philosophy
Improving the Image Quality in Compressed Sensing MRI by the Exploitation of Data Properties
Associate Advisor
Other advisors: Professor Feng Liu
-
2015
Master Philosophy
The Design of Radiofrequency Coils for a MRI-LINAC System
Associate Advisor
Other advisors: Professor Feng Liu
-
2014
Doctor Philosophy
Exploitation of Sparsity in Compressed Sensing MRI
Associate Advisor
Other advisors: Professor Feng Liu
-
2014
Doctor Philosophy
Split-gradient coil design and analysis for hybrid MRI-involved system
Associate Advisor
Other advisors: Professor Feng Liu
-
2013
Doctor Philosophy
Computational Electromagnetics-tailored Inverse Solution to Radiofrequency Issues of High Field MRI
Associate Advisor
Other advisors: Professor Feng Liu
-
-
2010
Doctor Philosophy
Computer Aided Analysis of Dynamic Contrast Enhanced MRI of Breast Cancer
Associate Advisor
-
2010
Doctor Philosophy
Analysis of Snore Sound Pitch and Total Airway Response in Obstructive Sleep Apnoea Hypopnoea Detection
Associate Advisor
Other advisors: Dr Udantha Abeyratne
-
2008
Doctor Philosophy
Radar Target Recognition based on Ultra Wideband Transient Electromagnetic Scattering
Associate Advisor
-
2005
Master Philosophy
PROCESSING OF SNORE RELATED SOUNDS FOR THE DIAGNOSIS OF OBSTRUCTIVE SLEEP APNOEA (OSA)
Associate Advisor
Other advisors: Dr Udantha Abeyratne
Media
Enquiries
Contact Emeritus Professor Stuart Crozier directly for media enquiries about:
- Bioelectromagnetics
- Biomedical engineering
- Magnetic Resonance Imaging (MRI)
- Magnetic resonance spectroscopy
- MRI
- RF engineering
- Spectroscopy - magnetic resonance
- Superconducting magnet design
Need help?
For help with finding experts, story ideas and media enquiries, contact our Media team: